Код неисправности Bizhub PRESS 1250/1250P/1052/PRO 951 (MALFUNCTION CODE)
bizhub PRO 951
Classification |
Malfunction |
Cause |
Main body: Drive abnormality |
C-0001 |
Main body drive serial input abnormality 1. Within a specified period of time after the power ON, a serial data is not received between the printer control board (PRCB) and the main body drive board. |
|
C-0002 |
Main body drive serial input abnormality 2. Within a specified period of time after the power ON, a serial data is not received between the printer control board (PRCB) and the main body drive board. |
|
C-0003 |
Main body drive serial input abnormality 3. Within a specified period of time after the power ON, a serial data is not received between the printer control board (PRCB) and the main body drive board. |
|
C-0004 |
Main body drive serial input abnormality4. Within a specified period of time after the power ON, a serial data is not received between the printer control board (PRCB) and the main body drive board. |
Main body: Communication error |
C-0005 |
Drive communication reception error detection abnormality 3. |
|
C-0006 |
Drive communication reception error detection abnormality 4. |
|
C-0007 |
Drive communication reception error detection abnormality 5. |
|
C-0008 |
Drive communication reception error detection abnormality 6. |
|
C-0010 |
Drive communication reception error detection abnormality 2. |
|
C-0011 |
Drive communication reception error detection abnormality 8. |
|
C-0012 |
Drive communication reception error detection abnormality 9. |
|
C-0020 |
ADU drive serial input abnormality 1. In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received. |
|
C-0021 |
ADU drive serial input abnormality 2. In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received. |
|
C-0022 |
ADU drive serial input abnormality 3. In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received. |
|
C-0023 |
Drive communication reception error detection abnormality 0. |
|
C-0024 |
Drive communication reception error detection abnormality 7. |
|
C-0025 |
Drive communication reception error detection abnormality 11. |
Main body: Drive abnormality |
C-0101 |
Paper feed motor (M4) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M4 was turned ON. |
PF: Drive |
C-0103 |
1st tandem PF-703/706 paper feed motor (M1) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON. |
Main body: Power abnormality |
C-0104 |
Abnormality of the vertical conveyance motor (M8) power in the printer control board (PRCB). An error detection signal (blowout of ICP) of M8 is detected when M8 is turned ON. |
PF: Power abnormality |
C-0105 |
Abnormality of the PF exit conveyance motor (M2) power in the PF drive board (PFUDB) of the 1st tandem PF-706. An error detection signal (blowout of ICP) of M2 is detected when M2 is turned ON. |
PF: Drive |
C-0106 |
2nd tandem PF-703/706 paper feed motor speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON. |
PF: Power abnormality |
C-0107 |
Abnormality of the PF exit conveyance motor (M2) power in the PF drive board (PFUDB) of the 2nd tandem PF-706. An error detection signal (blowout of ICP) of M2 is detected when M2 is turned ON. |
|
C-0108 |
Abnormality of the PF conveyance motor (M3) power in the PF drive board (PFUDB) of the 1st tandem PF-703. An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON. |
|
C-0109 |
Abnormality of the PF conveyance motor (M3) power in the PF drive board (PFUDB) of the 2nd tandem PF-703. An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON. |
Main body: Power abnormality |
C-0110 |
Abnormality of the registration section motor IC in the ADU drive board (ADUDB). The error detection signals of the ADU conveyance motor /2 (M16), the registration motor (M17) and the loop motor (M18) are detected after the print is started. |
|
C-0111 |
Abnormality of the duplex section motor IC in the ADU drive board (ADUDB). The error detection signals of the ADU reverse motor (M12), the reverse/exit motor (M13), the ADU accelerate motor (M14) and the ADU conveyance motor /1 (M15) are detected after the print is started. |
|
C-0112 |
Vertical conveyance motor IC abnormality in the printer control board (PRCB) An error detection signal of vertical conveyance motor (M8) is detected after the print starts. |
|
C-0113 |
Abnormality 1 of the SD/ CL_24V power for the printer control board (PRCB) tray. At the start, the error detection signals of the PRCB tray solenoid/clutch ICP blowout and 24V cut off are detected. |
|
C-0114 |
Abnormality 2 of the SD/ CL_24V power for the printer control board (PRCB) tray. When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start. |
|
C-0115 |
Abnormality 1 of the SD/ CL_24V power for the printer control board (PRCB) vertical conveyance. At the start, the error detection signals of the PRCB vertical conveyance solenoid/clutch ICP blowout and 24V cut off are detected. |
|
C-0116 |
Abnormality 2 of the SD/ CL_24V power for the printer control board (PRCB) tray. When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start. |
PF: Power abnormality |
C-0118 |
Abnormality of the power for the PF drive board |
|
|
(PFUDB) SD/CL of the PF-703/706. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected. |
Main body: Drive |
C-0119 |
The transfer belt cleaning motor (M5) speed abnormality. The M5EM error detection signal is detected twice in succession within a specified period of time after M5 was turned ON. |
|
C-0120 |
Paper exit conveyance motor (M31) speed abnormality. The M31EM error detection signal is detected twice in succession within a specified period of time after M31 was turned ON. |
|
C-0121 |
Paper exit motor (M20) speed abnormality. The M20EM error detection signal is detected twice in succession within a specified period of time after M20 was turned ON. |
PF: Power abnormality |
C-0130 |
PF-703 coupling conveyance motor /1 (M4) power abnormality. An error detection signal (blowout of ICP) of M4 is detected when M4 is turned ON. |
|
C-0131 |
PF-703 coupling conveyance motor /2 and / 3 (M5 and M6) power abnormality. An error detection signal (blowout of ICP) of M5 and M6 is detected when M5 and M6 are turned ON. |
|
C-0132 |
Abnormality of the power for the PF drive board (PFUDB) SD/CL of the 2nd tandem PF-703/706. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected. |
PF: Drive |
C-0133 |
1st tandem PF-703 paper feed belt motor (M2) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON. |
|
C-0134 |
2nd tandem PF-703 paper feed belt motor (M2) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON. |
PI-PFU: Drive |
C-0140 |
Paper feed motor speed abnormality of PI-PFU (PF-703) tandem PF. |
|
|
An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON. |
PI-PFU: Power abnormality |
C-0141 |
PI-PFU (PF-703) PF exit conveyance motor (M3) power abnormality. An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON. |
|
C-0142 |
PI-PFU (PF-703) coupling conveyance motor /1 (M4) power abnormality. An error detection signal (blowout of ICP) of M4 is detected when M4 is turned ON. |
|
C-0143 |
PI-PFU (PF-703) coupling conveyance motor /2 and / 3 (M5 and M6) power abnormality. An error detection signal (blowout of ICP) of M5 and M6 is detected when M5 and M6 are turned ON. |
|
C-0144 |
PI-PFU (PF-703) SD/CL power abnormality. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected. |
PI-PFU: Drive |
C-0145 |
PI-PFU (PF-703) paper feed belt motor (M2) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON. |
LU |
C-0150 |
An abnormal speed signal of the paper feed motor (M101) is checked. An error detection signal is detected twice in succession a specified period of time after M101 was turned ON (the first signal is ignored). |
|
C-0151 |
The locking of the paper lift motor (M100) is detected. When M100 is ON, an error detection signal of the M100 is detected in succession for 1 second. |
LU: Power source abnormality |
C-0152 |
Abnormality of the paper lift motor (M100) power in the LU drive board (LUDB). An error detection signal (blowout of ICP) of M100 is detected. |
|
C-0153 |
Abnormality of the solenoid and clutch power in the LU drive board (LUDB). An error detection signals (blowout of ICP) of the pick up solenoid (SD100), the paper feed clutch (CL101), and the preregistration clutch (CL102) are detected after the print is started. |
Main body: Trayl |
C-0201 |
Trayl: up abnormality When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the tray lift-up motor /1 (M25) turns ON for lifting operation. At this time, an error detection signal (24V cut off) is detected. |
|
C-0203 |
Tray1 up abnormality 2. When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the tray lift-up motor /1 (M25) turns ON for lifting operation. At this time, an error detection signal is not detected. |
|
C-0204 |
The locking of the tray lift- up motor /1 (M25) is detected. An error detection signal of M25 is detected while M25 is ON. |
Main body: Tray2 |
C-0205 |
Tray2 up abnormality 1. When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the tray lift-up motor /2 (M34) turns ON for lifting operation. At this time, an error detection signal (24V cut off) is detected. |
|
C-0207 |
Tray /2 up abnormality 2. When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the tray lift-up motor /2 (M34) turns ON for lifting operation. At this time, an error detection signal is not detected. |
|
C-0208 |
The locking of the tray lift- up motor /2 (M34) is detected. When M34 is ON, an error detection signal of the M34 is detected. |
PF: Tray3 |
C-0222 |
1st tandem PF-703/706 upper tray up abnormality. PF-703: When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20 seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and / Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting. PF-706: When the upper limit sensor /1 (PS2) is OFF, PS2 does not turn ON within 20 seconds after the paper lift motor /1 (M42) turns ON for the lifting operation. |
|
C-0223 |
The locking of the paper lift motor /1 of the 1st tandem PF-703/706 upper tray (M7: PF-703, M42: PF-706) is detected. When M7 and M42 are ON, error detection signals of the M7 and M42 are detected. |
PF: Tray4 |
C-0226 |
1st tandem PF-703/706 middle tray up abnormality. PF-703: When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20 seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and / Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting. PF-706: When the upper limit sensor /2 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the paper lift motor /2 (M43) turns ON for the lifting operation. |
|
C-0227 |
The locking of the paper lift motor /2 of the 1st tandem PF-703/706 middle tray (M8: PF-703, M43: PF-706) is detected. When M8 and M43 are ON, error detection signals of the M8 and M43 are detected. |
PF: Tray5 |
C-0230 |
1st tandem PF-703/706 lower tray up abnormality. PF-703: When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20 seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and / Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting. PF-706: When the upper limit sensor /3 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for the lifting operation. |
|
C-0231 |
The locking of the paper lift motor /3 of the 1st tandem PF-703/706 lower tray (M9: PF-703, M44: PF-706) is detected. When M9 and M44 are ON, error detection signals of the M9 and M44 are detected. |
PF: Tray6 |
C-0240 |
2nd tandem PF-703/706 upper tray up abnormality. PF-703: When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20 seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and / Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting. PF-706: When the upper limit sensor /1 (PS2) is OFF, PS2 does not turn ON within 20 seconds after the paper lift motor /1 (M42) turns ON for the lifting operation. |
|
C-0241 |
The locking of the paper lift motor /1 of the 2nd tandem PF-703/706 upper tray (M7: PF-703, M42: PF-706) is detected. When M7 and M42 are ON, error detection signals of the M7 and M42 are detected. |
PF: Tray7 |
C-0242 |
2nd tandem PF-703/706 middle tray up abnormality. PF-703: When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20 seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and / Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting. PF-706: When the upper limit sensor /2 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the paper lift motor /2 (M43) turns ON for the lifting operation. |
|
C-0243 |
The locking of the paper lift motor /2 of the 2nd tandem PF-703/706 middle tray (M8: PF-703, M43: PF-706) is detected. When M8 and M43 are ON, error detection signals of the M8 and M43 are detected. |
PF: Tray8 |
C-0244 |
2nd tandem PF-703/706 lower tray up abnormality. PF-703: When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20 seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and / Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting. PF-706: When the upper limit sensor /3 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for the lifting operation. |
|
C-0245 |
The locking of the paper lift motor /3 of the 2nd tandem PF-703/706 lower tray (M9: PF-703, M44: PF-706) is detected. When M9 and M44 are ON, error detection signals of the M9 and M44 are detected. |
PI-PFU: PI Tray1 |
C-0250 |
PI-PFU (PF-703) upper tray up abnormality. When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20 seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and / Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting. |
|
C-0251 |
The locking of the upper tray paper lift motor /1 (M7) is detected. When M7 is ON, an error detection signal of the M7 is detected. |
PI-PFU: PI Tray2 |
C-0252 |
PI-PFU (PF-703) middle tray up abnormality. When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20 seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and / Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting. |
|
C-0253 |
The locking of the upper tray paper lift motor /2 (M8) is detected. When M8 is ON, an error detection signal of the M8 is detected. |
PI-PFU: PI Tray3 |
C-0254 |
PI-PFU (PF-703) lower tray up abnormality. When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20 seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and / Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting. |
|
C-0255 |
The locking of the upper tray paper lift motor /3 (M9) is detected. When M9 is ON, an error detection signal of the M9 is detected. |
PF: Tray3 |
C-0261 |
1st tandem PF-703 shutter motor /1 (M10) operation time abnormality 1. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0262 |
1st tandem PF-703 shutter motor /1 (M10) operation time abnormality 2. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
PF: Tray4 |
C-0263 |
1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 1. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0264 |
1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 2. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
PF: Tray5 |
C-0265 |
1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 1. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0266 |
1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 2. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
PF: Tray6 |
C-0271 |
2nd tandem PF-703 shutter motor /1 (M10) operation time abnormality 1. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0272 |
2nd tandem PF-703 shutter motor /1 (M10) operation time abnormality 2. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
PF: Tray7 |
C-0273 |
2nd tandem PF-703 shutter motor /2 (M11) operation time abnormality 1. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0274 |
2nd tandem PF-703 shutter motor /2 (M11) operation time abnormality 2. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
PF: Tray8 |
C-0275 |
2nd tandem PF-703 shutter motor /3 (M12) operation time abnormality 1. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0276 |
2nd tandem PF-703 shutter motor /3 (M12) operation time abnormality 2. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
PI-PFU: PI Tray1 |
C-0281 |
PI-PFU (PF-703)shutter motor /1 (M10) operation time abnormality 1. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0282 |
PI-PFU (PF-703)shutter motor /1 (M10) operation time abnormality 2. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
PI-PFU: PI Tray2 |
C-0283 |
PI-PFU (PF-703)shutter motor /2 (M11) operation time abnormality 1. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0284 |
PI-PFU (PF-703)shutter motor /2 (M11) operation time abnormality 2. The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
PI-PFU: PI Tray3 |
C-0285 |
PI-PFU (PF-703)shutter motor /3 (M12) operation time abnormality 1. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected. |
|
C-0286 |
PI-PFU (PF-703)shutter motor /3 (M12) operation time abnormality 2. The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
Main body: Fan abnormality |
C-0304 |
Paper exit cooling fan /Up (FM4) rotation abnormality + 24V power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-0306 |
Paper exit cooling fan /Up (FM4) rotation abnormality. The FM4 EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
C-0307 |
Paper exit cooling fan /Lw1 (FM10) rotation abnormality + 24V power abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-0309 |
Paper exit cooling fan /Lw1 (FM10) rotation abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. In addition, error detection signal (24 V cut off) is not detected. |
|
C-0310 |
Paper exit cooling fan /Lw2 (FM28) rotation abnormality + 24V power abnormality. The FM28EM error detection signal is detected twice in succession within a specified period of time after FM28 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-0312 |
Paper exit cooling fan /Lw2 (FM28) rotation abnormality. The FM28 EM error detection signal is detected twice in succession within a specified period of time after FM28 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
C-0320 |
Paper feed assist fan /Rr1 (FM20) rotation abnormality + 24V power abnormality. The FM20 EM error detection signal is detected twice in succession within a specified period of time after FM20 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
С-0З22 |
Paper feed assist fan /Rr1 (FM20) rotation abnormality. The FM20 EM error detection signal is detected twice in succession within a specified period of time after FM20 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
С-0З2З |
Paper feed assist fan /Fr1 (FM21) rotation abnormality + 24V power abnormality. The FM21 EM error detection signal is detected twice in succession within a specified period of time after FM21 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
С-0З25 |
Paper feed assist fan /Fr1 (FM21) rotation abnormality. The FM21 EM error detection signal is detected twice in succession within a specified period of time after FM21 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
C-0326 |
Paper feed assist fan /Rr2 (FM24) rotation abnormality + 24V power abnormality. The FM24 EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-0328 |
Paper feed assist fan /Rr2 (FM24) rotation abnormality. The FM24 EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
С-0З29 |
Paper feed assist fan /Fr2 (FM23) rotation abnormality + 24V power abnormality. The FM23 EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
С-0ЗЗ1 |
Paper feed assist fan /Fr2 (FM23) rotation abnormality. The FM23 EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, error detection signal (24V cut off) is not detected. |
PF : fan abnormality |
С-0З41 |
1st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0342 |
1st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
С-0З44 |
1st tandem PF-703/706 paper feed assist fan /Rr1 (FM2) power abnormality. The EM error detection signal of FM2 is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0345 |
1st tandem PF-703/706 paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0347 |
1st tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) power abnormality. The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0348 |
1st tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) rotation abnormality. The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0350 |
1st tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) power abnormality. The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0351 |
1st tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) rotation abnormality. The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
С-0З5З |
1st tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) power abnormality. The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
С-0З54 |
1st tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) rotation abnormality. The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0356 |
1st tandem PF-703/706 paper feed assist fan /Rr3 (FM10: PF-703, FM6: PF-706) power abnormality. The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0357 |
1st tandem PF-703/706 paper feed assist fan /Rr3 (FM10: PF-703, FM6: PF-706) rotation abnormality. The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0359 |
1st tandem PF-703/706 cooling fan power abnormality. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-706: The FM7 EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0360 |
1st tandem PF-703/706 cooling fan rotation abnormality 1. PF-703: The FM19 EM and FM20 EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected. PF-706: The FM20 EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan (FM7) turns ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0361 |
1st tandem PF-703 cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0370 |
2st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
С-0З71 |
2nd tandem PF-703/706 paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
С-0З72 |
Paper feed assist fan /Fr1 (FM2: PF-703) |
|
С-0З7З |
2nd tandem PF-703/706 paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0374 |
2nd tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) power abnormality. The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0375 |
2nd tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) rotation abnormality. The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0376 |
2nd tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) power abnormality. The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
С-0З77 |
2nd tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) rotation abnormality. The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
С-0З78 |
2nd tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) power abnormality. The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
С-0З79 |
2nd tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) rotation abnormality. The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0380 |
2nd tandem PF-703/706 paper feed assist fan /Rr3 (FM10: PF-703, FM6: PF-706) power abnormality. The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0381 |
2nd tandem PF-703/706 paper feed assist fan /Rr3 (FM10 PF-703, FM6: PF-706) rotation abnormality. The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0382 |
2nd tandem PF-703/706 cooling fan power abnormality. PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. PF-706: The FM7 EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0383 |
2nd tandem PF-703/706 cooling fan rotation abnormality 1. PF-703: The FM19 EM and FM20 EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected. PF-706: The FM20 EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan (FM7) turns ON. However, an error detection signal (blowout of ICP) is not detected. |
|
С-0З84 |
2nd tandem PF-703 cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected. |
PI-PFU : Fan abnormality |
С-0З85 |
PI-PFU (PF-703) paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
С-0З86 |
PI-PFU (PF-703) paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0387 |
PI-PFU (PF-703) paper feed assist fan /Rr1 (FM2) power abnormality. The EM error detection signal of FM2 is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
С-0З88 |
PI-PFU (PF-703) paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0389 |
PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) power abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0390 |
PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) rotation abnormality. The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0391 |
PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0392 |
PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) rotation abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0393 |
PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) power abnormality. The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0394 |
PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) rotation abnormality. The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0395 |
PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) power abnormality. The EM error detection signal of FM10 is detected twice in succession within a specified period of time after FM10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0396 |
PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) rotation abnormality. The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0397 |
PI-PFU (PF-703) cooling fan power abnormality. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0398 |
PI-PFU (PF-703) cooling fan rotation abnormality 1. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0399 |
PI-PFU (PF-703) cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected. |
Main body:Power abnormality |
C-0403 |
12V power abnormality in the printer control board (PRCB). An error detection signal of the 12V in PFDB (blowout of ICP) is detected. |
|
C-0404 |
5V power abnormality in the printer control board (PRCB). An error detection signal of the 5V in PRCB (blowout of ICP) is detected. |
|
C-0410 |
12V power abnormality in the ADU drive board (ADUDB). An error detection signal of the ADUDB (blowout of ICP) is detected. |
|
C-0411 |
ADU drive board (ADUDB) power abnormality 1. An error detection signal (blowout of ICP) of the transfer paper correction sensor (PS4), transfer exposure lamp (L4) or SD is detected. At this time, an error detection signal (24V cut off) is detected. |
|
C-0412 |
ADU drive board (ADUDB) power abnormality 2. An error detection signal (blowout of ICP) of the transfer paper correction sensor (PS4), transfer exposure lamp (L4) or SD is detected. However, an error detection signal (24V cut off) is not detected. |
|
C-0413 |
Interlock power abnormality of the ADU drive board (ADUDB). An error signal of the 24V interlock power is detected in the door detection closed status. |
Main body: Centering sensor abnormality |
C-0414 |
During the centering censor (PS4) is ON, the centering data does not sent from the ADU drive board though more than 5 sheets are processed in succession. |
PF: PF power source abnormality |
C-0420 |
PF drive board (PFUDB: PF-703/706) |
|
C-0421 |
Abnormality of the 12V power for the PF drive board (PFUDB) of the 2nd tandem PF-703/706. An error detection signal of the PFUDB (blowout of 12V ICP) is detected. |
|
C-0422 |
Abnormality of the 24V power for the PF drive board (PFUDB) of the 1st tandem PF-703/706. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected. |
|
C-0423 |
Abnormality of the 24V power for the PF drive board (PFUDB) of the 2nd tandem PF-703/706. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected. |
PI-PFU: Power abnormality |
C-0424 |
Abnormality of the 12V power for the PF drive board (PFUDB) of PI-PFU (PF-703). An error detection signal of the PFUDB (blowout of 12V ICP) is detected. |
|
C-0425 |
Abnormality of the 24V power for the PF drive board (PFUDB) of PI-PFU (PF-703). While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected. |
PF: PF power source abnormality |
C-0501 |
1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0502 |
1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0503 |
1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0504 |
1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0505 |
1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0506 |
1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0507 |
1st tandem PF-703 paper leading edge separation fan /Rr1 (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0508 |
1st tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0509 |
1st tandem PF-703 paper leading edge separation fan /Rr2 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0510 |
1st tandem PF-703 paper leading edge separation fan /Rr2 (FM8) rotation abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0511 |
1st tandem PF-703 paper leading edge separation fan /Rr3 (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0512 |
1st tandem PF-703 paper leading edge separation fan /Rr3 (FM12) rotation abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0513 |
1st tandem PF-703 paper suction fan /1 (FM13) power abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0514 |
1st tandem PF-703 paper suction fan /1 (FM13) rotation abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0515 |
1st tandem PF-703 paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0516 |
1st tandem PF-703 paper suction fan /3 (FM15) rotation abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0517 |
1st tandem PF-703 paper suction fan /5 (FM17) power abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0518 |
1st tandem PF-703 paper suction fan /5 (FM17) rotation abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0519 |
1st tandem PF-703 paper suction fan /1 (FM14) power abnormality. The EM error detection signal of FM14 is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0520 |
1st tandem PF-703 paper suction fan /1 (FM14) rotation abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0521 |
1st tandem PF-703 paper suction fan /3 (FM16) power abnormality. The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0522 |
1st tandem PF-703 paper suction fan /3 (FM16) rotation abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0523 |
1st tandem PF-703 paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0524 |
1st tandem PF-703 paper suction fan /5 (FM18) rotation abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0525 |
2nd tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0526 |
2nd tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0527 |
2nd tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0528 |
2nd tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0529 |
2nd tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0530 |
2nd tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0531 |
2nd tandem PF-703 paper leading edge separation fan /Rr1 (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0532 |
2nd tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0533 |
2nd tandem PF-703 paper leading edge separation fan /Rr2 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0534 |
2nd tandem PF-703 paper leading edge separation fan /Rr2 (FM8) rotation abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0535 |
2nd tandem PF-703 paper leading edge separation fan /Rr3 (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0536 |
2nd tandem PF-703 paper leading edge separation fan /Rr3 (FM12) rotation abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0537 |
2nd tandem PF-703 paper suction fan /1 (FM13) power abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0538 |
2nd tandem PF-703 paper suction fan /1 (FM13) rotation abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0539 |
2nd tandem PF-703 paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0540 |
2nd tandem PF-703 paper suction fan /3 (FM15) rotation abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0541 |
2nd tandem PF-703 paper suction fan /5 (FM17) power abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0542 |
2nd tandem PF-703 paper suction fan /5 (FM17) rotation abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0543 |
2nd tandem PF-703 paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0544 |
2nd tandem PF-703 paper suction fan /1 (FM14) rotation abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0545 |
2nd tandem PF-703 paper suction fan /3 (FM16) power abnormality. The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0546 |
2nd tandem PF-703 paper suction fan /3 (FM16) rotation abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0547 |
2nd tandem PF-703 paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0548 |
2nd tandem PF-703 paper suction fan /5 (FM18) rotation abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0561 |
PI-PFU (PF-703) paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0562 |
PI-PFU (PF-703) paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0563 |
PI-PFU (PF-703) paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0564 |
PI-PFU (PF-703) paper leading edge separation fan /Fr2 (FM7) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0565 |
PI-PFU (PF-703) paper leading edge separation fan /Fr3 (FM11) power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0566 |
PI-PFU (PF-703) paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0567 |
PI-PFU (PF-703) paper leading edge separation fan /Rr1 (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0568 |
PI-PFU (PF-703) paper leading edge separation fan /Rr1 (FM4) rotation abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0569 |
PI-PFU (PF-703) paper leading edge separation fan /Rr2 (FM8) power abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0570 |
PI-PFU (PF-703) paper leading edge separation fan /Rr2 (FM8) rotation abnormality. The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0571 |
PI-PFU (PF-703) paper leading edge separation fan /Rr3 (FM12) power abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0572 |
PI-PFU (PF-703) paper leading edge separation fan /Rr3 (FM12) rotation abnormality. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0573 |
PI-PFU (PF-703) paper suction fan /1 (FM13) power abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0574 |
PI-PFU (PF-703) paper suction fan /1 (FM13) rotation abnormality. The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0575 |
PI-PFU (PF-703) paper suction fan /3 (FM15) power abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0576 |
PI-PFU (PF-703) paper suction fan /3 (FM15) rotation abnormality. The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0577 |
PI-PFU (PF-703) paper suction fan /5 (FM17) power abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0578 |
PI-PFU (PF-703) paper suction fan /5 (FM17) rotation abnormality. The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0579 |
PI-PFU (PF-703) paper suction fan /1 (FM14) power abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0580 |
PI-PFU (PF-703) paper suction fan /1 (FM14) rotation abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0581 |
PI-PFU (PF-703) paper suction fan /3 (FM16) power abnormality. The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0582 |
PI-PFU (PF-703) paper suction fan /3 (FM16) rotation abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0583 |
PI-PFU (PF-703) paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected. |
|
C-0584 |
PI-PFU (PF-703) paper suction fan /5 (FM18) rotation abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0601 |
1st tandem PF-703 dehumidifier fan /Rt1 (FM22) rotation abnormality. The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0602 |
PI-PFU (PF-703) dehumidifier fan /Lt1 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0603 |
1st tandem PF-703 dehumidifier fan /Rt2 (FM24) rotation abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0604 |
1st tandem PF-703 dehumidifier fan /Lt2 (FM25) rotation abnormality. The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0605 |
1st tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0606 |
1st tandem PF-703 dehumidifier fan /Lt3 (FM27) rotation abnormality. The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0611 |
2nd tandem PF-703 dehumidifier fan /Rt1 (FM22) rotation abnormality. The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0612 |
2nd tandem PF-703 dehumidifier fan /Lt1 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0613 |
2nd tandem PF-703 dehumidifier fan /Rt2 (FM24) rotation abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0614 |
2nd tandem PF-703 dehumidifier fan /Lt2 (FM25) rotation abnormality. The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0615 |
2nd tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0616 |
2nd tandem PF-703 dehumidifier fan /Lt3 (FM27) rotation abnormality. The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0621 |
PI-PFU (PF-703) dehumidifier fan /Rt1 (FM22) rotation abnormality. The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0622 |
PI-PFU (PF-703) dehumidifier fan /Lt1 (FM23) rotation abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
С-062З |
PI-PFU (PF-703) dehumidifier fan /Rt2 (FM24) rotation abnormality. The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0624 |
PI-PFU (PF-703) dehumidifier fan /Lt2 (FM25) rotation abnormality. The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0625 |
PI-PFU (PF-703) dehumidifier fan /Rt3 (FM26) rotation abnormality. The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-0626 |
PI-PFU (PF-703) dehumidifier fan /Lt3 (FM27) rotation abnormality. The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
PF: Heater high temperature abnormality |
C-0631 |
1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal. |
|
C-0632 |
1st tandem PF-703 dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal. |
|
C-0633 |
1st tandem PF-703 dehumidification heater /3 (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal. |
|
C-0634 |
1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C. |
|
C-0635 |
1st tandem PF-703 dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C. |
|
C-0636 |
1st tandem PF-703 dehumidification heater /3 (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C. |
PF: Heater low temperature abnormality |
C-0637 |
1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
|
C-0638 |
1st tandem PF-703 dehumidification heater /2 (HTR2) low temperature software abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
|
C-0639 |
1st tandem PF-703 dehumidification heater /3 (HTR3) low temperature software abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
PF: Heater temperature rise abnormality |
C-0640 |
1st tandem PF-703 dehumidification heater /1 (HTR1) temperature rise abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
|
C-0641 |
1st tandem PF-703 dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
|
C-0642 |
1st tandem PF-703 dehumidification heater /3 (HTR3) temperature rise abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
PF: Heater high temperature abnormality |
C-0651 |
2nd tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal. |
|
C-0652 |
2nd tandem PF-703 dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal. |
|
C-0653 |
2nd tandem PF-703 dehumidification heater /3 (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal. |
|
C-0654 |
2nd tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C. |
|
C-0655 |
2nd tandem PF-703 dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C. |
|
C-0656 |
2nd tandem PF-703 dehumidification heater /3 (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C. |
PF: Heater low temperature abnormality |
C-0657 |
2nd tandem PF-703 dehumidification heater /1 (HTR1) low temperature hardware abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
|
C-0658 |
2nd tandem PF-703 dehumidification heater /2 (HTR2) low temperature software abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
|
C-0659 |
2nd tandem PF-703 dehumidification heater /3 (HTR3) low temperature software abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
PF: Heater temperature rise abnormality |
C-0660 |
2nd tandem PF-703 dehumidification heater /1 (HTR1) temperature rise abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
|
C-0661 |
2nd tandem PF-703 dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
|
C-0662 |
2nd tandem PF-703 dehumidification heater /3 (HTR3) temperature rise abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
PF: Heater high temperature abnormality |
C-0671 |
PI-PFU (PF-ГОЗ) dehumidification heater /1 (HTR) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal. |
|
C-0672 |
PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal. |
|
C-0673 |
PI-PFU (PF-ГОЗ) dehumidification heater /З (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal. |
|
C-0674 |
PI-PFU (PF-ГОЗ) dehumidification heater /1 (HTR) high temperature software abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C. |
|
C-0675 |
PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C. |
|
C-0676 |
PI-PFU (PF-703) dehumidification heater /З (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C. |
PF: Heater low temperature abnormality |
C-0677 |
PI-PFU (PF-ГОЗ) dehumidification heater /1 (HTR1) low temperature software abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
|
C-0678 |
PI-PFU (PF-ГОЗ) dehumidification heater /2 (HTR2) low temperature software abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
|
C-0679 |
PI-PFU (PF-703) dehumidification heater /3 (HTR3) low temperature software abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON. |
PF: Heater temperature rise abnormality |
C-0680 |
PI-PFU (PF-703) dehumidification heater /1 (HTR1) temperature rise abnormality. The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
|
C-0681 |
PI-PFU (PF-703) dehumidification heater /2 (HTR2) temperature rise abnormality. The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
|
C-0682 |
PI-PFU (PF-703) dehumidification heater /3 (HTR3) temperature rise abnormality. The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON. |
Finishing: Communication error |
C-1001 |
Serial communication error between the main body and the finishing option. |
FS: FS-532 abnormality |
C-1005 |
Communication error. |
FD: FD abnormality |
C-1006 |
Communication error. |
SD: SD-506 abnormality |
C-1007 |
Communication error. |
PB: PB abnormality |
C-1009 |
Communication error between Main CPU in the PB control board (PBCB) and Sub CPU1. |
|
C-1010 |
Communication error between Main CPU in the PB control board (PBCB) and Sub CPU2. |
PB control board (PBCB) |
C-1011 |
Paper feed error between the main body and PB. |
GP : GP-501 abnormality |
C-1012 |
Communication abnormality. |
RU: RU-509 abnormality |
C-1013 |
Communication error. |
RU: RU-510 abnormality |
C-1014 |
Communication error. |
FS: FS-532 abnormality |
C-1102 |
The tray up down motor (M11) does not turn OFF even when a specified period of time elapses after it starts operations. Or, it operates for more than the allowed time at a speed out of the specified one. |
|
C-1103 |
The stacker alignment home sensor (PS12) does not turn ON within a specified period of time after the home position search operation of the stacker alignment motor (M9) starts. |
|
C-1105 |
The paper exit opening unit does not get to the specified opening position within a specified period of time after the paper exit opening motor (M10) starts operations. |
|
C-1106 |
The stapler movement home sensor (PS22) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M14) starts. |
|
C-1109 |
The stapler home sensor (PS40) does not turn ON within a specified period of time after the stapler motor (M31) starts operations. |
|
C-1113 |
The stacker rear stopper home sensor (PS27) does not turn ON within a specified period of time after the home position search operation of the stacker movement motor (M19) starts. |
|
C-1114 |
The rewind paddle release home sensor (PS38) does not turn ON even after a specified period of time after the rewind paddle release home motor (M28) starts the home position search operation. |
FS: FS-510 abnormality |
C-1115 |
The 1st folding knife home sensor (PS110) does not turn ON within a specified period of time after thelst |
|
|
folding knife motor (M107) turns ON. |
PI: PI abnormality |
C-1124 |
The tray upper limit sensor /Lw (PS209) or the tray lower limit sensor /Lw (PS210) does not turn ON within a specified period of time after the tray lift motor /Lw (M202) turns ON. |
|
C-1125 |
The tray upper limit sensor /Up (PS205) or the tray lower limit sensor /Up (PS204) does not turn ON within a specified period of time after the tray up down motor /Up (M201) turns ON. |
PK: PK abnormality |
C-1127 |
The punch shift home sensor (PS303) does not turn ON within a specified period of time after the punch shift motor (M302) turns ON. |
ZU: ZU-608 abnormality |
C-1130 |
1st folding stopper home sensor (PS603) does not turned ON within a specified period of time after the 1st folding stopper motor (M602) starts the home position search operation. |
|
C-1131 |
2nd folding stopper home sensor (PS604) does not turned ON within a specified period of time after the 2nd folding stopper motor (M603) starts the home position search operation. |
PK: PK abnormality |
C-1132 |
The punch home sensor (PS301) does not turn ON within a specified period of time after the punch motor (M301) turns ON. |
ZU: ZU-608 abnormality |
C-1133 |
The punch shift home sensor (PS605) does not turn ON even after a specified period of time after the punch shift motor (M605) starts the home position search operation. |
|
C-1134 |
An error detection signal of FM601 is detected continuously for a specified period of time while the main motor cooling fan (FM601) is ON. |
|
C-1135 |
After the punch motor (M604) turns ON, M604 does not turn ON within a specified period of time. |
ZU: ZU-608 abnormality |
C-11З6 |
After the punch switchover motor (M608) turns ON, punch switchover switch (MS601) does not turn ON from OFF, or not turn OFF from ON within a specified period of time. |
FS: FS-532 abnormality |
C-1137 |
The conveyance gate home sensor (PS31) does not turn ON within a specified period of time after the conveyance gate motor (M22) turns ON. |
|
C-1141 |
After the stack assist motor (M8) turns ON, the stack assist home sensor (PS11) does not turn ON within a specified period of time. |
|
C-1144 |
The paper exit alignment plate home sensor (PS20) does not turn ON within a specified period of time after the paper exit alignment plate motor (M12) turns ON. |
|
C-1147 |
The paper exit alignment plate up down home sensor (PS21) does not turn ON within a specified period of time after the paper exit alignment plate up down motor (M13) turns ON. |
|
C-1153 |
The main tray home sensor (PS23) does not turn ON within a specified period of time after the tray shift roller motor (M15) turns ON. |
|
C-1154 |
After the gripper exit sensor /Lw (M16) turns ON, the gripper home sensor /Up (PS24) does not turn ON within a specified period of time. |
|
C-1155 |
After the gripper exit sensor /Lw (M17) turns ON, the gripper home sensor /Lw (PS25) does not turn ON within a specified period of time. |
|
C-1156 |
After the stacker rear stopper motor (M20) turns ON, the stacker rear stopper home sensor (PS29) does not turn ON within a specified period of time. |
|
C-1157 |
After the stacker paper press motor (M21) turns ON, the stacker paper press home sensor (PS30) does not turn ON within a specified period of time. |
|
C-1158 |
After the roller pressure motor (M27) turns ON, the roller pressure motor home sensor (PS34) does not turn ON within a specified period of time. |
|
C-1159 |
The bypass gate home sensor (PS36) does not turn ON within a specified period of time after the bypass gate motor (M25) turns ON. |
|
C-1170 |
The exit paper press home sensor (PS37) does not turn ON within a specified period of time after the exit paper press motor (M26) turns ON. |
|
C-1171 |
The small size paper alignment home sensor (PS26) does not turn ON within a specified period of time after the small size paper alignment motor (M18) turns ON. |
|
C-1172 |
An error detection signal of FM1 is detected continuously for a specified period of time while the large size paper alignment fan (FM1) is ON. |
FS: FS-510 abnormality |
C-1173 |
The stapler shift home sensor (PS105) does not turn ON within a specified period of time after the stapler movement motor (M103) turns ON. |
|
C-1174 |
The operation does not complete within a specified period of time after the SD saddle stapler motor (M102) starts operations, |
|
C-1175 |
After the stopper motor (M105) turns ON, the stopper home sensor (PS107) does not turn ON within a specified period of time. |
|
C-1176 |
After the center paddle motor (M106) turns ON, the center paddle home sensor (PS108) does not turn ON within a specified period of time. |
|
C-1177 |
The 2nd folding knife home sensor (PS111) does not turn ON within a specified period of time after the 2nd folding knife motor (M110) turns ON. |
FS: FS-532 abnormality |
C-1179 |
RUKA communication error |
FS: FS-510 abnormality |
C-1180 |
The alignment home sensor (PS106) does not |
|
|
turn ON within a specified period of time after the saddle stitching alignment motor (M104) turns ON. |
|
C-1181 |
After the lower paddle motor (M109) turns ON, the lower paddle home sensor (PS114) does not turn ON within a specified period of time. |
LS (1st tandem): LS abnormality |
C-1201 |
The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. |
|
C-1202 |
The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time. |
|
C-1203 |
The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. Or, PS12 does not turn ON within a specified period of time. |
|
C-1204 |
The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON. |
|
C-1205 |
The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. |
|
C-1206 |
The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. |
LS (2nd tandem): LS abnormality |
C-1211 |
The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. |
|
C-1212 |
The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time. |
|
C-1213 |
The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. Or, PS12 does not turn ON within a specified period of time. |
|
C-1214 |
The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON. |
|
C-1215 |
The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. |
|
C-1216 |
The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. |
FD: FD abnormality |
C-1221 |
The 1st folding cam home sensor (PS55) does not turn ON within a specified period of time after the 1st folding release motor (M14) turns ON. |
|
C-1222 |
The 2nd folding cam home sensor (PS56) does not turn ON within a specified period of time after the 2nd folding release motor (M15) turns ON. |
|
C-1223 |
The 3rd folding cam home sensor (PS57) does not turn ON within a specified period of time after the 3rd folding release motor (M16) turns ON. |
|
C-1224 |
The 2 holes punch home sensor (PS8) does not turn OFF within a specified period of time after the 2- holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 2 holes punch home sensor (PS8) does not turn OFF. |
|
C-1225 |
The 3 holes/4 holes punch home sensor (PS9) does not turn OFF within a specified period of time after the 3 holes/4 holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 3 holes/4 holes punch home sensor (PS9) does not turn OFF. |
|
C-1226 |
The alignment plate home sensor (PS10) does not turn ON within a specified period of time after the alignment plate home position return operation starts. Or, after the alignment motor (M12) turns ON, the alignment plate home sensor (PS10) does not turn OFF. |
|
C-1227 |
The punch registration home sensor (PS11) does not turn ON within a specified period of time after the punch registration claw home position return operation starts. Or, after the punch registration motor (M13) turns ON, the punch registration home sensor (PS11) does not turn OFF. |
|
C-1228 |
The main tray upper limit sensor (PS20) does not turn ON within a specified period of time after the main tray home position search starts. Or, after the tray up down motor (M11) turns ON, the main tray upper limit sensor (PS20) does not turn OFF. |
|
C-1229 |
The main tray lower limit sensor (PS22) does not turn ON within a specified period of time after the tray up down motor (M11) is in the down operation. |
|
C-1230 |
After the FD paper lift motor /Up (M8) is in the down operation, the PI lift plate home sensor /Up (PS34) does not turn ON within a specified period of time. Or, after the paper lift motor /Up (M8) is in the up operation, the PI tray upper limit sensor /Up (PS32) does not turn ON. |
|
C-1231 |
After the FD paper lift motor /Lw (M9) is in the down operation, the PI lift plate home sensor /Lw (PS40) does not turn ON within a specified period of time. Or, after the paper lift motor /Lw (M9) is in the up operation, the PI upper limit sensor /Lw (PS38) does not turn ON. |
|
C-1232 |
An error detection signal is detected continuously for a specified period of time while the entrance conveyance motor (M1) is ON. |
|
C-1233 |
An error detection signal of M3 is detected continuously for a specified period of time while the intermediate conveyance motor (M3) is ON. |
|
C-1234 |
An error detection signal of M7 is detected continuously for a specified period of time while the PI conveyance motor (M7) is ON. |
|
C-1235 |
An error detection signal of M17 is detected continuously for a specified period of time while the main tray exit motor (M17) is ON. |
SD: SD-506 abnormality |
C-1241 |
The scraps press home sensor (PS48) does not turn ON within a specified period of time after the bundle exit motor (M5) starts the home position search operation. |
|
C-1242 |
The folding main scan alignment home sensor / Fr1 (PS18) does not turn ON within a specified period of time after the folding main scan alignment motor /Fr (M7) starts the home position search operation. Or, even after a specified period of time after M7 starts the operation, it does not stop. |
|
C-1243 |
The folding exit home sensor (PS24) does not turn ON within a specified period of time after the folding sub scan alignment exit motor (M8) starts the home position search operation. Or, even after a specified period of time after M8 starts to decelerate, it does not stop. |
|
C-1244 |
The saddle stitching alignment home sensor /Rt (PS28) does not turn ON within a specified period of time after the saddle stitching alignment motor / Rt (M9) starts the home position search operation. Or, even after a specified period of time after M9 starts the operation, it does not stop. |
|
C-1245 |
The bundle arm home sensor (PS32) does not turn ON within a specified period of time after the bundle arm motor (M10) starts the home position search operation. Or, even after a specified period of time after M10 starts the operation, it does not stop. |
|
C-1246 |
The bundle clip upper limit sensor (PS33) does not turn ON within a specified period of time after the bundle clip motor (M11) starts the home position search operation. Or, even after a specified period of time after M11 starts the operation, it does not stop. |
|
C-1247 |
The bundle registration home sensor (PS34) does not turn ON within a specified period of time after the bundle registration motor (M12) starts the home position search operation. Or, even after a specified period of time after M12 starts the operation, it does not stop. |
|
C-1248 |
The overlap home sensor (PS17) does not turn ON within a specified period of time after the overlap motor (M13) starts the home position search operation. Or, even after a specified period of time after M13 starts the operation, it does not stop. |
|
C-1249 |
The folding main scan alignment home sensor /Rr (PS19) does not turn ON within a specified period of time after the folding main scan alignment motor /Rr (M14) starts the home position search operation. Or, even after a specified period of time after M14 starts the operation, it does not stop. |
|
C-1250 |
The stapler movement home sensor (PS25) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M15) starts. Or, even after a specified period of time after M15 starts the operation, it does not stop. |
|
C-1251 |
The saddle stitching alignment home sensor /Lt (PS29) does not turn ON within a specified period of time after the saddle stitching alignment motor / Lt (M16) starts the home position search operation. Or, even after a specified period of time after M16 starts the operation, it does not stop. |
|
C-1252 |
The bundle press movement home sensor (PS36) does not turn ON within a specified period of time after the bundle press movement motor (M17) starts the home position search operation. Or, even after a specified period of time after M17 starts the operation, it does not stop. |
|
С-125З |
The 1st folding blade home sensor (PS21) does not turn ON within a specified period of time after the 1st folding blade motor (M18) starts the home position search operation. Or 1st folding blade home sensor /1 (PS20) does not turned ON within a specified period of time after M18 starts the operation. |
|
C-1254 |
The 2nd folding blade home sensor /2 (PS23) does not turn ON within a specified period of time after the 2nd folding blade motor (M19) starts the home position search operation. Or the 2nd folding blade home sensor /1 (PS22) does not turned ON within a specified period of time after M19 starts the operation. |
|
C-1255 |
The clincher up down home sensor (PS26) does not turn ON even after a specified period of time after the clincher up down motor (M20) starts the home position search. Or, even after a specified period of time after M20 starts the operation, it does not stop. |
|
C-1256 |
The saddle stitching press home sensor (PS27) does not turn ON within a specified period of time after the saddle stitching press motor (M21) starts the home position search operation. Or, even after a specified period of time after M21 starts the operation, it does not stop. |
|
C-1257 |
The bundle arm rotation home sensor (PS31) does not turn ON within a specified period of time after the bundle arm rotation motor (M22) starts the home position search operation. Or, even after a specified period of time after M22 starts the operation, it does not stop. |
|
C-1258 |
The bundle press home sensor (PS37) does not turn ON within a specified period of time after the bundle press motor (M23) starts the home position search operation. Or, even after a specified period of time after M23 starts the operation, it does not stop. |
|
C-1259 |
The bundle press home sensor (PS35) does not turn ON within a specified period of time after the bundle press stage up down motor (M24) starts the home position search operation. Or PS35 or the bundle press stage up down upper limit sensor (PS45) does not turned ON after a specified period of time M24 starts the operation. |
|
C-1260 |
The guide shaft home sensor (PS46) does not turn ON even after a specified period of time after the guide shaft motor (M25) starts the home position search operation. Or, even after a specified period of time after M25 starts the operation, it does not stop. |
|
C-1261 |
The stapler home sensor / Rt (HS1) or the clincher start sensor /Rt (HS2) does not turn ON even after a specified period of time after the stapler motor /Rt (M29) starts the operation. |
|
C-1262 |
The stapler home sensor / Lt (HS3) or the clincher start sensor /Lt (HS4) does not turn ON even after a specified period of time after the stapler motor /Lt (M30) starts the operation. |
|
C-1263 |
It does not stop even after a specified period of time after the trimmer blade motor (M31) starts the operation. |
|
C-1264 |
It does not stop even after a specified period of time after the trimmer press motor (M32) starts the operation. |
|
C-1265 |
It does not stop even after a specified period of time after the bundle arm assist motor (M26) starts the operation. |
|
C-1266 |
Rotation abnormality is detected for a specified period of time in succession while the entrance conveyance motor (M1) is driving. |
|
C-1267 |
Rotation abnormality is detected for a specified period of time in succession while the horizontal conveyance motor (M2) is driving. |
|
C-1268 |
Rotation abnormality is detected for a specified period of time in succession while the folding entrance motor (M3) is driving. |
|
C-1269 |
Rotation abnormality is detected for a specified period of time in succession while the folding transfer motor (M4) is driving. |
|
C-1270 |
Rotation abnormality is detected for a specified period of time in succession while the bundle exit motor (M5) is driving. |
|
C-1271 |
Rotation abnormality is detected for a specified period of time in succession while the folding sub scan alignment exit motor (M8) is driving. |
|
C-1272 |
Rotation abnormality is detected for a specified period of time in succession while the trimmer paddle motor (M33) is driving. |
|
C-1273 |
The trimmer completion sensor (PS62) does not turn ON even after a specified period of time after the trimmer blade motor (M31) is in the up operation. |
|
C-1275 |
The wire slack sensor (PS66) detected the slack of the trimmer edge drive wire. |
RU: RU-510 abnormality |
C-1281 |
FD alignment motor (M3) drive abnormality. The CD alignment home sensor (PS3) does not turn ON even after a specified period of time after M3 starts the home position search operation. Or, even after a specified period of time after M3 starts the operation, it does not stop. |
|
C-1282 |
CD alignment motor (M4): drive abnormality. The CD alignment home sensor (PS4) does not turn ON even after a specified period of time after M4 starts the home position search operation. Or, even after a specified period of time after M4 starts the operation, it does not stop. |
RU: RU-509 abnormality |
C-1290 |
Rotation abnormality is detected for a specified period of time in succession while the decurler conveyance motor (M3) is driving. |
|
C-1291 |
The home position search operation of the de-curler pressure motor /Lw (M5) does not complete within a specified period of time. |
|
C-1292 |
The home position search operation of the de-curler pressure motor /Up (M6) does not complete within a specified period of time. |
|
C-1293 |
Rotation abnormality is detected for a specified period of time in succession while the humidification section conveyance motor (M8) is driving. |
|
C-1294 |
The home position search operation of the humidification section roller pressure motor /Rt (M9) does not complete within a specified period of time. |
|
C-1295 |
The home position search operation of the humidification section roller pressure motor /Lt (M10) does not complete within a specified period of time. |
|
C-1299 |
The water tank full sensor (PS13) detects ON continuously for more than a specified period of time. |
LS (1st tandem): LS abnormality |
C-1301 |
An error detection signal is detected continuously for a |
|
|
specified period of time while the paper cooling fan motor /Fr (FM1) is ON. |
|
C-1302 |
An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /1 (FM2) is ON. |
|
C-1303 |
An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor/Mi (FM3) is ON. |
|
C-1304 |
An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON. |
|
C-1305 |
An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan motor /Rr (FM5) is ON. |
LS (2nd tandem): LS abnormality |
C-1306 |
An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Fr (FM1) is ON. |
|
C-1307 |
An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor/1 (FM2) is ON. |
|
C-1308 |
An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Mi (FM3) is ON. |
|
C-1309 |
An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON. |
|
C-1310 |
An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan motor /Rr (FM5) is ON. |
SD: SD-506 abnormality |
C-1311 |
A rotation error detection signal is detected continuously for specified period of time while the scraps removal fan motor (FM1) is started or driving. |
LS (3rd tandem): LS abnormality |
C-1316 |
An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Fr (FM1) is ON. |
|
C-1317 |
An error detection signal is detected continuously for a specified period of time while the paper cooling fan /1 (FM2) is ON. |
|
C-1318 |
An error detection signal is detected continuously for a specified period of time while the paper cooling fan /Mi (FM3) is ON. |
|
C-1319 |
An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON. |
|
C-1320 |
An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan /Rr (FM5) is ON. |
PB: PB abnormality |
C-1330 |
A rotation error detection signal is detected continuously for specified time period while the cover paper tray fan /1 (FM71) is started or driving. |
|
C-1331 |
A rotation error detection signal is detected continuously for specified time period while the cover paper tray fan /2 (FM72) is started or driving. |
|
C-1332 |
A rotation error detection signal is detected continuously for a specified time period while the exhaust fan /1 (FM80) is started or driving. |
|
C-1333 |
A rotation error detection signal is detected continuously for a specified time period while the exhaust fan /2 (FM81) is started or driving. |
|
C-1334 |
A rotation error detection signal is detected continuously for specified period of time while the pellet supply cooling fan (FM4) is started or driving. |
RU: RU-510 abnormality |
C-1341 |
Stack assist fan /Fr (FM1) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM1 operation. |
|
C-1342 |
Stack assist fan /Rr (FM2) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM2 operation. |
RU: RU-509 abnormality |
C-1351 |
Error detection signals of FM/1, FM/2 and FM/3 are detected continuously for a specified period of time while the entrance paper fans /1 (FM1), /2 (FM2) and /3 (FM3) are ON. |
|
C-1352 |
Error detection signals of FM4 and FM5 are detected continuously for a specified period of time while the ventilation assist fans /1 (FM4) and /2 (FM5) are ON. |
|
C-1353 |
Error detection signals of FM15, FM16 and FM17 are detected continuously for a specified period of time while the entrance paper fans /4 (FM15), /5 (FM16) and /6 (FM17) are ON. |
|
C-1354 |
Error detection signals of FM18, FM19 and FM20 are detected continuously for a specified period of time while the entrance paper fans /7 (FM18), /8 (FM19) and /9 (FM20) are ON. |
|
C-1355 |
Error detection signals of FM21 is detected continuously for a specified period of time while the ventilation assist fan /3 (FM21) is ON. |
|
C-1356 |
An error detection signal of FM6 is detected continuously for a specified period of time while the humidification section paper fan /1 (FM6) is ON. |
|
C-1357 |
An error detection signal of FM7 is detected continuously for a specified period of time while the humidification section paper fan /2 (FM7) is ON. |
|
C-1358 |
An error detection signal of FM8 is detected continuously for a specified period of time while the humidification section paper fan /3 (FM8) is ON. |
|
C-1359 |
An error detection signal of FM9 is detected continuously for a specified period of time while the humidification section paper fan /4 (FM9) is ON. |
|
C-1360 |
An error detection signal of FM10 is detected continuously for a specified period of time while the humidification section paper fan /5 (FM10) is ON. |
|
C-1361 |
An error detection signal of FM11 is detected continuously for a specified period of time while the humidification section paper fan /6 (FM11) is ON. |
|
C-1364 |
An error detection signal of FM14 is detected continuously for a specified period of time while the humidification section paper fan (FM14) is ON. |
FS: FS-532 abnormality |
C-1402 |
Non-volatile memory abnormality. |
FD: FD abnormality |
C-1403 |
Non-volatile memory abnormality. |
SD: SD-506 abnormality |
C-1404 |
Non-volatile memory abnormality. |
PB: PB abnormality |
C-1406 |
Non-volatile memory abnormality in the PB control board (PBCB) |
RU: RU-509 abnormality |
C-1407 |
Non-volatile memory abnormality. |
RU: RU-510 abnormality |
C-1408 |
Non-volatile memory abnormality. |
SD: SD-506 abnormality |
C-1411 |
5V power abnormality in the SD drive board (SDDB) |
FS: FS-532 abnormality |
C-1412 |
24V activation failure |
FD: FD abnormality |
C-1432 |
Communication error in FD |
SD: SD-506 abnormality |
C-1433 |
Communication error in SD |
PB: PB abnormality |
C-1435 |
Message queue full or the control abnormality of Sub CPU1 in the PB control board (PBCB) |
|
C-1436 |
Message queue full or the control abnormality of Sub CPU2 in the PB control board (PBCB) |
|
C-1437 |
Message queue of the communication among tasks in the PB is full. |
RU: RU-509 abnormality |
C-1438 |
Communication error in RU |
RU: RU-510 abnormality |
C-1439 |
Communication error in RU |
FS: FS-532/ SD-510 abnormality |
C-1442 |
Communication error between FS-532 and SD-510. |
FD: FD abnormality |
C-1451 |
When the FD is unready, a signal to start operations is received from the main body. |
SD: SD-506 abnormality |
C-1452 |
When the SD is unready, a signal to start operations is received from the main body. |
PB: PB abnormality |
C-1454 |
PB operation prohibition abnormality. PB received operation start signal from the main body when the PB is unready. |
RU: RU-509 abnormality |
C-1455 |
When RU is unready, a signal to start operations is received from the main body. |
RU: RU-510 abnormality |
C-1456 |
When RU is unready, a signal to start operations is received from the main body. |
|
C-1499 |
Logical contradiction error |
PB: PB abnormality |
C-1501 |
The entrance conveyance has not been completed within a specified period of time after the entrance conveyance motor (M1) turns ON. |
|
C-1502 |
A rotation error detection signal is detected for a specified period of time in succession while the intermediate conveyance motor (M2) is driving. |
|
C-1504 |
The SC entrance conveyance has not been completed within a specified period of time after the SC entrance conveyance motor (M11) turns ON. |
|
C-1505 |
The switchback conveyance has not been completed within a specified period of time after the SC switchback conveyance motor (M12) turns ON. |
|
C-1506 |
The switchback roller release operation has not been completed within a specified period of time after the SC switchback release motor (M13) turns ON. |
|
C-1507 |
The SC alignment has not been completed within a specified period of time after SC alignment motor (M15) turns ON. |
|
C-1508 |
The SC paper bundle conveyance has not been completed within a specified period of time after the SC bundle conveyance motor (M17) turns ON. |
|
C-1509 |
The SC roller release operation has not been completed within a specified period of time after the SC roller release motor (M18) turns ON. |
|
C-1510 |
The SC entrance movement operation has not been completed within a specified period of time after the clamp entrance movement motor (M19) turns ON. |
|
C-1511 |
The clamp entrance roller release operation has not been completed within a specified period of time after the clamp entrance roller release motor (M20) turns ON. |
|
C-1512 |
The clamp alignment has not been completed within a specified period of time after clamp alignment motor (M21) turns ON. |
|
C-1513 |
The clamp section open/ close operation has not been completed within a specified period of time after the clamp motor (M22) turns ON. |
|
C-1514 |
The clamp rotation operation has not been completed within a specified period of time after the clamp rotation motor (M23) turns ON. |
|
C-1515 |
The glue tank movement operation has not been completed within a specified period of time after the glue tank movement motor (M31) turns ON. |
|
C-1516 |
A rotation error detection signal is detected for a specified period of time in succession while the glue apply roller motor (M32) is driving. |
|
C-1517 |
The count of a specified number of pellets, which is counted by the pellet supply passage sensor (PS37), has not been reached after the pellet supply pipe motor (M33) turns ON. |
|
C-1518 |
The operation of the pellet supply arm has not been completed within a specified period of time after the pellet supply arm motor (M34) turns ON. |
|
C-1519 |
The alignment in the cover paper table up/down section has not been completed within a specified period of time after the cover paper alignment motor (M41) turns ON. |
|
C-1520 |
The booklet exit has not been completed within a specified period of time after the booklet exit motor (M42) turns ON. |
|
C-1521 |
The driven arm /Rt swing operation start has not been completed within a specified period of time after the cover paper conveyance arm motor /Rt (M43) turns ON |
|
C-1522 |
The driven arm /Lt swing operation start has not been completed within a specified period of time after the cover paper conveyance arm motor /Lt (M44) turns ON |
|
C-1523 |
The cover paper conveyance start has not been completed within a specified period of time after cover paper conveyance motor (M45) turns ON. |
|
C-1524 |
The cover paper table up or down movement has not been completed within a specified period of time after the cover paper table up down motor /Fr (M46) turns ON. |
|
C-1525 |
The cover paper table up or down movement has not been completed within a specified period of time after the cover paper table up down motor /Rr (M47) turns ON. |
|
C-1526 |
The movement of the cover paper folding plate / Rt has not been completed within a specified period of time after the cover paper folding motor /Rt (M48) turns ON. |
|
C-1527 |
The movement of the cover paper folding plate / Lt has not been completed within a specified period of time after the cover paper folding motor /Lt (M49) turns ON. |
|
C-1528 |
The trimming of the cover paper has not been completed within a specified period of time after the cutter motor (M50) turns ON. |
|
C-1530 |
The booklet movement of the booklet conveyance section has not been completed within a specified period of time after the booklet conveyance belt motor (M61) turns ON. |
|
C-1531 |
The size changing operation of the carriage section has not been completed within a specified period of time after the booklet conveyance belt movement motor (M62) turns ON. |
|
C-1532 |
The up/down movement operation of the carriage section has not been completed within a specified period of time after the booklet conveyance belt up down motor (M63) turns ON. |
|
C-1534 |
The booklet rear edge pressing process has not been completed within a specified period of time after the booklet stopper motor (M65) turns ON. |
|
C-1537 |
The tray moving up process has not been completed within a specified period of time after the cover paper tray lift motor (M73) turns ON. |
|
C-1538 |
The cover paper feed has not been completed within a specified period of time after the cover paper feed motor (M74) turns ON. |
|
C-1540 |
After the warm-up is started, temperature detected by the glue tank temperature sensor /Md (TH3) has not risen to a prescribed level within a specified time period. |
|
C-1541 |
After the warm-up is started, temperature detected by the glue tank temperature sensor /Lw (TH4) has not risen to a prescribed level within a specified time period. |
|
C-1542 |
After the warm-up is started, temperature detected by the glue apply roller temperature sensor (TH1) has not risen to a prescribed level within a specified time period. |
|
C-1543 |
After the pellet supply, temperature detected by the glue tank temperature sensor /Up (TH2) has not risen to a prescribed level within a specified period of time. |
|
C-1544 |
During standby, after the glue tank heater (H1) is turned ON, temperature detected by the glue tank temperature sensor /Md (TH3) has not risen to a prescribed level within a specified time period. |
|
C-1545 |
When the prescribed temperature is obtained and after the glue tank heater (H1) is turned ON, temperature detected by the glue tank temperature sensor /Lw (TH4) has not risen to a prescribed level within a specified time period. |
|
C-1546 |
When the prescribed temperature is obtained and after the glue tank heater (H1) is turned ON, temperature detected by the glue apply roller temperature sensor (TH1) has not risen to a prescribed level within a specified time period. |
|
C-1547 |
The glue apply roller temperature sensor (TH1) detects an abnormal high temperature. |
|
C-1548 |
The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature. |
|
C-1549 |
The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature. |
|
C-1550 |
The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature. |
|
C-1551 |
The glue apply roller temperature sensor (TH1) detects an abnormal high temperature (hardware) TH1 detects an abnormal high temperature of the glue apply roller. |
|
C-1552 |
The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature (hardware). TH2 detects an abnormal high temperature of the glue tank. |
|
C-1553 |
The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature (hardware). TH3 detects an abnormal high temperature of the glue tank. |
|
C-1554 |
The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature (hardware). TH4 detects an abnormal high temperature of the glue tank. |
|
C-1555 |
After warming-up is completed, the glue apply roller temperature sensor (TH1) detects an abnormal low temperature. |
|
C-1556 |
When glue supply control temperature is reached, the glue tank temperature sensor /Up (TH2) detects an abnormal low temperature. |
|
C-1557 |
After warming-up is completed, the glue tank temperature sensor /Md (TH3) detects an abnormal low temperature. |
|
C-1558 |
After warming-up is completed, the glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature. |
|
C-1559 |
The glue apply roller temperature sensor (TH1) detects an abnormal low temperature (hardware). After warming-up is completed, TH1 detects the glue apply roller error signal of abnormal low temperature. |
|
C-1560 |
The glue tank temperature sensor /Up (TH2) detects an abnormal low temperature (hardware). After glue supply control temperature is reached, TH2 detects the glue tank error signal of abnormal low temperature. |
|
C-1561 |
The glue tank temperature sensor /Md (TH3) detects an abnormal low temperature (hardware). After warming-up is completed, TH3 detects the glue tank error signal of abnormal low temperature. |
|
C-1562 |
The glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature (hardware). After warming-up is completed, TH4 detects the glue tank error signal of abnormal low temperature. |
|
C-1565 |
Relay conveyance motor drive abnormality |
|
C-1566 |
Relay conveyance exit motor drive abnormality A rotation error detection signal is detected for a specified period of time in succession while the relay conveyance exit motor (M91) is driving. |
|
C-1567 |
Pellet supply pipe motor drive abnormality The pellet supply pipe has not completed the operations within a specified period of time after the pellet supply pipe motor (M33) turns ON. |
LS (3rd tandem): LS abnormality |
C-1651 |
The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. |
|
C-1652 |
The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time. |
|
C-1653 |
The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. Or, PS12 does not turn ON within a specified period of time. |
|
C-1654 |
The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON. |
|
C-1655 |
The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. |
|
C-1656 |
The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. |
Main body: Wire cleaning abnormality |
C-2101 |
Charger cleaning motor (M23) operation time abnormality. |
Main body : Wire cleaning abnormality |
C-2102 |
Charger cleaning motor (M23) power abnormality. |
Main body: Wire cleaning abnormality |
C-2103 |
Charger cleaning motor (M23) drive abnormality. |
Main body: Motor abnormality |
C-2201 |
Toner bottle motor (M6) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M6 was turned ON. |
|
C-2202 |
Developing motor (M3) speed abnormality. Since an error detection signal is detected a second after M3 turns ON, turn OFF M3 for 0.5 seconds. Then, an error detection signal is detected again a second after it is turned ON again. |
|
C-2203 |
The locking of the blade motor (M22) is detected. The error detection signal (over current) of M22 is detected. |
|
C-2204 |
Drum motor (M2) drive abnormality + 24V power abnormality. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal (24V cut off) is detected. |
|
C-2205 |
Drum motor (M2) power abnormality. The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal (blowout of ICP) of the blade motor (M22) is detected. |
|
C-2206 |
Drum motor (M2) drive abnormality. |
|
C-2207 |
Drum motor (M22) drive abnormality + 24V power abnormality. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (24V cut off) is detected. |
|
C-2208 |
Blade motor (M22) power abnormality. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (blowout of ICP) of the blade motor (M22) is detected. |
|
C-2209 |
It is checked that the movement of the blade motor (M22) is not completed. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal is not detected. |
|
C-2210 |
The drum motor (M2) does not start. The drum READY2 signal (READY signal) is not detected within a specified period of time after M2 turns ON. |
|
C-2211 |
Intermediate hopper motor (M11) power abnormality. An error detection signal (blowout of ICP) is detected when M11 turns ON. |
|
C-2212 |
Air separation motor (M10) power abnormality. An error detection signal (blowout of ICP) is detected when M10 turns ON. |
|
C-2213 |
Air separation motor (M10) rotation abnormality. Since an error is detected when M10 turns ON, turn it OFF. An error is still detected when turn it ON again. |
|
C-2214 |
The toner conveyance abnormality is detected. When executing the toner supply operation for 8 minutes, the intermediate hopper toner remaining sensor (PS39) does not turn ON and the hopper toner remaining sensor /2 (PS33) detects ON in succession for 15 seconds. |
|
C-2215 |
Hopper toner remaining sensor /2 (PS33) abnormality. When the toner is supplied for 8minutes, it is found that the toner remaining sensor /1 (PS32) does not turn ON and the hopper toner remaining sensor /2 (PS33) turns OFF for the last 15 seconds in succession. |
|
C-2217 |
Leakage at the mixing section is detected. When the toner pump motor (M28) is operating, the cup section toner remaining sensor (PS34) detects the toner being provided in succession for seconds. |
|
C-2220 |
Toner pump motor (M28) rotation abnormality + 24V power abnormality. While M28 is rotating, an error detection signal (abnormal rotation/24V cut off) is detected for more than 1second. |
|
C-2221 |
Toner pump motor (M28) power abnormality. While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an abnormality signal (blowout of ICP) is detected, but no abnormality signal (24V cut off) is detected. |
|
C-2222 |
Toner pump motor (M28) rotation abnormality. While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error detection signal (blowout of ICP/24V cut off) is not detected. |
|
C-2224 |
Air pump motor (M29) rotation abnormality + 24V power abnormality. While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error signal (24V cut off) is detected. |
|
C-2225 |
Air pump motor (M29) power abnormality. While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an abnormality signal (blowout of ICP) is detected, but no abnormality signal (24V cut off) is detected. |
|
C-2226 |
Air pump motor (M29) rotation abnormality. While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected. |
|
C-2227 |
Developing screw motor (M21) rotation abnormality. The M21EM error detection signal is detected twice in succession within a specified period of time after M21 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-2228 |
The transfer belt motor (M30) rotation abnormality. The M30EM error detection signal is detected twice in succession within a specified period of time after M30 was turned ON. However, an error detection signal (blowout of ICP) is not detected. |
|
C-2230 |
Waste toner box swing motor (M19) drive abnormality. The waste toner box swing sensor (PS15) ON or OFF is not detected twice in succession within a specified period of time after M19 turns ON. |
|
C-2231 |
De-curler motor (M32) rotation abnormality. The M32EM error detection signal is detected twice in succession within a specified period of time after M32 was turned ON, and the main door detection is Close. |
|
C-2233 |
Waste toner box swing motor (M19) rotation abnormality. The M19EM error detection signal is not detected twice in succession within a specified period of time after M19 was turned ON. |
|
C-2234 |
Transfer belt pressure release motor (M26) operation time abnormality 1. When M26 moves from the HP position to the pressure position, the transfer pressure position sensor /1 or /2 (PS55 or PS56) does not turn ON within a specified period of time. At this time, the main door detection is Close. |
|
C-2235 |
Transfer belt pressure release motor (M26) operation time abnormality 2. |
|
C-2236 |
Abnormality of the transfer belt pressure release motor (M26) IC in the ADU drive board (ADUDB). An error detection signal of M26 is detected after the print is started. |
|
C-2237 |
Waste toner motor (M9) rotation abnormality. The M9EM error detection signal is detected twice in succession within a specified period of time after M9 was turned ON. |
|
C-2238 |
Blade motor (M22) abnormality. Waste blade motor does not move to the weak pressure position within a specified period of time after M22 turns ON. |
|
C-2241 |
Abnormality of the intermediate hopper motor (M11) drive in the printer control board (PRCB). |
|
C-2242 |
Drum cleaner motor (M35) abnormality The M35 EM error detection signal is detected twice in succession within a specified period of time after M35 was turned ON. |
Main body: Fan abnormality |
C-2304 |
Developing suction fan (FM22) rotation abnormality + 24V power abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-2306 |
Developing suction fan (FM22) rotation abnormality. The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
C-2307 |
Developing cooling fan /Up (FM31) rotation abnormality + 24V power abnormality. The FM31EM error detection signal is detected twice in succession within a specified period of time after FM31 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-2309 |
Developing cooling fan (FM31) rotation abnormality. The FMx EM error detection signal is detected twice in succession within a specified period of time after FMx was turned ON. However, error detection signal (24V cut off) is not detected. |
|
C-2311 |
Developing cooling fan (FM11) rotation abnormality + 24V power abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-2313 |
Pump cooling fan (FM11) rotation abnormality. The FM11 EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
C-2317 |
Charger exhaust fan (FM44) rotation abnormality + 24V power abnormality. The FM44 EM error detection signal is detected twice in succession within a specified period of time after FM44 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-2318 |
Charger exhaust fan (FM44) rotation abnormality. The FM44 EM error detection signal is detected twice in succession within a specified period of time after FM44 was turned ON. However, error detection signal (24V cut off) is not detected. |
Main body:Power abnormality |
C-2401 |
The fall-off of the erase lamp (EL) CN is detected. When turning ON the power, an error detection signal (fall-off) is detected a specified period of time after the fall-off detection control signal of the EL CN turns ON. |
Main body: Drum |
C-2402 |
Drum temperature sensor wiring harness breakage. When the change in temperature of the drum temperature sensor (TH5) is less than -2°C a specified period of time after the main power switch (SW1) turns ON to start the control of the dehumidification heater /1 (HTR1) and the drum temperature is below 10°C after 1minute. |
|
C-2403 |
Drum temperature sensor wiring harness breakage. When the main power switch (SW1) turns ON with the fusing temperature below 50°C, the detected temperature of the drum temperature sensor (TH5) is more than 52°C, and when the detected temperature is above 52°C after a specified period of time. |
|
C-2411 |
TCR sensor (TCRS) output abnormality 1. The TCRS output is detected more than 3.0V (153step) in printing. |
|
C-2412 |
TCR sensor (TCRS) output abnormality 2. The TCRS output is detected more than 0.5V (25step) in printing. |
|
C-2413 |
TCR sensor (TCRS) output abnormality 3. |
Main body: High voltage power source abnormality |
C-2701 |
A charge leak is detected. After a charge EM signal abnormality is detected while in the charge ON, up to 5 charge ON/OFF operations occur in succession while in 10 prints. |
|
C-2702 |
A transfer leak is detected. After a transfer EM signal abnormality is detected while in the charge ON, up to 5 transfer ON/OFF operations occur in succession while in 10 prints. |
|
C-2704 |
24V high voltage power abnormality. An error detection signal (blowout of ICP) of 24V high voltage power is detected. At this time, the main door detection and the PFU door detection are Close. |
|
C-2705 |
PCC leak is detected. After a PCC EM signal abnormality is detected while in the PCC ON, up to 5 transfer ON/OFF operations occur in succession while in 10 prints. |
Main body: Process abnormality |
C-2801 |
IDC sensor (TCB) dirt correction abnormality. While in the maximum density correction (Dmax), the IDC sensor (TCB) dirt correction abnormality is detected 10 times in succession. |
|
C-2802 |
The maximum density correction (Dmax) is not completed. While in Dmax, the number of rotations of the developing sleeve gets to the maximum. |
|
C-2803 |
The IDC sensor (TCB) output abnormality. While in the maximum density correction (Dmax), a patch for control is not output. (No output is made from the gamma sensor.) |
|
C-2804 |
The dirt correction of the IDC sensor is not completed. |
|
C-2807 |
Drum potential sensor (DPS) output abnormality 1. The DPS detects the value less than the potential specified value of the unexposed part 5 times in succession. |
|
C-2808 |
Dot diameter correction abnormality. While in the dot diameter correction, the correction is terminated with an abnormal value. |
|
C-2809 |
Drum potential sensor (DPS) output abnormality 2. While in the 0V check of the DPS, more than 100V of the drum surface potential is detected more than 5 times. When this condition is detected 5 times in succession, the error code is displayed. |
|
C-2810 |
Drum potential sensor (DPS) output abnormality 3. While in the drum potential correction, a patch for control is not output with the V1 getting to more than 350V. When this condition is detected 5 times in succession, the error code is displayed. |
|
C-2811 |
Drum potential sensor (DPS) data abnormality. While in the drum potential correction, no convergence is obtained even after correction is made more than 10 times. When this condition is detected 5 times in succession, the error code is displayed. |
|
C-2812 |
Transfer current auto adjustment abnormality. The auto adjustment of the transfer current has not completed. |
|
C-2815 |
Developing bias auto adjustment abnormality. The auto adjustment of the developing bias has not completed. |
|
C-2816 |
Drum charger capacity deterioration. When the charger grid/ developing bias is in excess of the limit of correction, lower the developing potential/ fogging margin potential in steps of 50V. As a result, less than 50V of the difference with the target charger potential is detected 10 times in succession. |
|
C-2821 |
The toner supply prohibition status is not released 1. Even though the TCR sensor (TCRS) output increases, the number of the toner supply prohibition status continuity is detected 30 times, and more than 2.5V of the TCRS output value is detected. |
|
C-2822 |
The toner supply prohibition status is not released 2. The number of the toner supply prohibition status continuity becomes 100 times. |
Main body: Motor abnormality |
C-3102 |
Fusing pressure release motor (M33) operation time abnormality 1. When M33 moves from the release position to the pressure position, the fusing pressure home sensor (PS58) does not turn ON within a specified period of time.(PRO 951 is unimplemented) The same abnormality occurs when the fusing unit exclusively for PRO 951 is set to PRESS 1250/1250P/1052. |
|
C-3103 |
Fusing pressure release motor (M33) operation time abnormality 2. The fusing pressure home sensor (PS58) ON is not detected within a specified period of time after the main power turns ON. When M33 moves from the pressure position to the release position, PS58 does not turn ON within a specified period of time. (PRO 951 is unimplemented) The same abnormality occurs when the fusing unit exclusively for PRO 951 is set to PRESS 1250/1250P/1052. |
Main body: Fusing set abnormality |
C-3104 |
Abnormality when the fusing unit used exclusively for PRESS1250/1250P/1052 or EF-120 is set to PRO 951. An error is detected in the following conditions with the fusing unit used exclusively for PRESS1250/1250P/1052 or EF-102 is set to PRO 951. In case that either of the fusing pressure home sensor (PS58), fusing pressure position sensor /1 (PS59), fusing pressure position sensor /2 (PS60) and fusing pressure position sensor /3 (PS61) turns ON when both the ADU knob set and the fusing unit set are detected. |
Main body: Motor abnormality |
C-3201 |
Drum motor (M24) power abnormality + 24V power abnormality. When M24 turns ON, error detection signals (blowout of ICP and the 24V cut off) are detected. |
|
C-3202 |
Web motor (M24) power abnormality. An error detection signal (blowout of ICP) is detected when M24 turns ON. At this time, an error detection signal (24V cut off) is not detected. |
Main body: Fusing high temperature abnormality |
C-3501 |
Thermistor /1 (TH1) high temperature abnormality (software). TH1 detects a temperature of 244°C or above 10 times in a period of 0.5second. |
|
C-3502 |
Thermistor /3 (TH3) high temperature abnormality (software). TH3 detects a temperature of 230°C or above 5 times in a period of 1second. |
|
C-3503 |
Thermistor /1 (TH1) high temperature abnormality (hardware). TH1 detects the fusing abnormality detection 1. |
|
C-3504 |
Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 4. |
Main body: Fusing low temperature abnormality |
C-3801 |
Thermistor /1 (TH1) high temperature abnormality (software). TH1 does not get to 50°C when a specified period of time has elapsed after the main power switch (SW1) turns ON for the fusing ON control. |
|
C-3802 |
Thermistor /3 (TH3) high temperature abnormality (software). TH3 does not get to 50°C when a specified period of time has elapsed after the main power switch (SW1) turns ON for the fusing ON control. |
Main body: Fusing sensor abnormality |
C-3901 |
Thermistor /1 (TH1) high temperature abnormality (long time/software). TH1 detects a temperature of 240°C or above 60 times in a period of 0.5second. |
|
C-3902 |
Thermistor /3 (TH3) high temperature abnormality (long time/software). TH3 detects a temperature of 220°C or above 30 times in a period of 1second. |
|
C-3903 |
Thermistor /1 (TH1) high temperature abnormality 1 (hardware). TH1 detects the fusing abnormality detection signal 2. |
|
C-3904 |
Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 5. |
|
C-3905 |
Thermistor /1 (TH1) high temperature abnormality 1 (hardware). TH1 detects the fusing abnormality detection signal 3. |
|
C-3906 |
Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 6. |
Main body: Fan abnormality |
C-4301 |
Image processing cooling fan (FM12) rotation abnormality + 24V power abnormality. The abnormal status is detected twice in succession after FM12 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
С-4З0З |
Image processing cooling fan (FM12) rotation abnormality 1. The FM12 EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
C-4304 |
Image processing cooling fan (FM12) rotation abnormality 2. When the print is started, the EM signal of FM12 turns ON. |
|
C-4305 |
Charger suction fan (FM3) rotation abnormality + 24V power abnormality. The abnormal status is detected twice in succession after FM3 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-4307 |
Charger suction fan (FM3) rotation abnormality 1. The FM3 EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, error detection signal (24V cut off) is not detected. |
|
C-4314 |
Front cooling fan (FM18) rotation abnormality + 24V power abnormality. The abnormal status is detected twice in succession after FM18 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-4316 |
Front cooling fan (FM18) rotation abnormality. The FM26 EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, error detection signal (24V cut off) is not detected. |
Main body: Image processing abnormality |
C-4701 |
FIFO address abnormality for the printer. While in the image write, the expansion processing of image data that is read in is not correctly terminated. |
|
C-4702 |
Compression input FIFO abnormality. An error interrupt occurs with the compression/ expansion chip FIFO. |
|
C-4703 |
Elongation abnormality. Due to the elongation of data the compression of which is not completed, the destruction of the compressed data and the abnormal length of data, an elongation abnormality is detected. |
|
C-4705 |
Printer time out. |
|
C-4706 |
Expansion device access abnormality. While in the image write, despite of no resource provided, an inappropriate processing such as accessing to the elongation device is made. |
|
C-4708 |
Expansion device access abnormality. When accessing to the memory device, a defective software is detected. |
|
C-4709 |
Memory time out. |
|
C-4720 |
Shift amount abnormality while in the repeat. When the shift amount (used for cutting margin, etc.) while in the repeat is negative (-). |
|
C-4721 |
The Centering Adjustment is too late. The print operation starts before the paper centering adjustment is terminated. (The Centering Adjustment is too late) |
|
C-4722 |
The creation of the PWM gamma curve failed. A PWM gamma curve is not created properly. |
|
C-4725 |
LPH board (LPHB) connection abnormality. Due to the disconnection of the LPHB connector, no connection is available with the overall control board. |
|
C-4850 |
Segmentation abnormality. The overall control software accesses an illegal address. |
|
C-5010 |
Communication error between the overall control board (OACB) and the printer control board (PRCB). Any of the following error is detected during data reception between OACB and PRCB. |
Main body:Power abnormality |
C-5101 |
Fusing motor (M1) speed abnormality. An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON. |
Main body: Main relay operation malfanction |
C-5102 |
Monitor the detection signal of RL1 turning ON and 24 VICP blowout since the main tray (RL1) firstly turns ON after the power source turns ON, and detect the abonormality 5 times in a row during a specified period of time. |
Main body: Fan abnormality |
C-5311 |
Suction cooling fan /1 (FM6) rotation abnormality + 24V power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-5313 |
Suction cooling fan /1 (FM6) rotation abnormality 1. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (24V cut off) is not detected. |
|
C-5317 |
Cooling fan /1 (FM1) rotation abnormality + 24V power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-5319 |
Cooling fan /1 (FM1) rotation abnormality 1. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (24V cut off) is not detected. |
|
C-5320 |
Cooling fan /2 (FM2) rotation abnormality + 24V power abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-5322 |
Cooling fan /1 (FM1) rotation abnormality 1. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (24V cut off) is not detected. |
|
C-5326 |
Cooling fan /1 (FM1) rotation abnormality 2. When the print is started, the EM signal of FM1 turns ON. |
|
C-5327 |
Cooling fan /1 (FM1) rotation abnormality 2. When the print is started, the EM signal of FM2 turns ON. |
|
C-5328 |
Suction cooling fan /1 (FM6) rotation abnormality 2. When the print is started, the EM signal of FM6 turns ON. |
|
C-5329 |
Abnormality of the fan connected to ADU drive board. The EM error detection signal is detected twice in succession within a specified period of time after ADU cooling fan /1 (FM14), /3 (FM13), sensor cooling fan /1 (FM16) and registration cooling fan (FM17) connected to ADU drive board were turned ON. At this time, the door close detection of the door open/close sensor /1 (PS1), /2 (PS2) and PF door open/close sensor (PS70) is detected 10 times in succession. |
|
C-5330 |
Suction cooling fan /2 (FM7) rotation abnormality + 24V power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-5332 |
Suction cooling fan /2 (FM6) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (24V cut off) is not detected. |
|
C-5337 |
De-curler fan /1 (FM29) rotation abnormality. The FM29EM error detection signal is detected twice in succession within a specified period of time after FM29 was turned ON. At this time, the door close is detected. |
|
C-5338 |
De-curler fan /2 (FM30) rotation abnormality. The FM30EM error detection signal is detected twice in succession within a specified period of time after FM30 was turned ON. At this time, the door close is detected. |
|
C-5339 |
Transfer belt cleaning fan (FM27) rotation abnormality. When the print is started, the EM signal of FM27 turns ON. |
|
C-5340 |
Rotation abnormality of fans equipped in ADU. The EM error signal is detected twice in succession within a specified period of time after ADU cooling fan /2 (FM15), belt cooling fan (FM37) and reverse cooling fan (FM38) was turned ON. At this time, the door close is detected. |
|
С-5З41 |
Collection pipe cooling fan (FM34) rotation abnormality + 24V power abnormality. The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
С-5З4З |
Collection pipe cooling fan (FM34) rotation abnormality 1. The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. At this time, an error detection signal (24V cut off) is not detected. |
|
C-5344 |
Collection pipe cooling fan (FM34) rotation abnormality 2. When the print is started, the EM signal of FM34 turns ON. |
|
C-5345 |
Toner bottle cooling fan (FM35) rotation abnormality + 24V power abnormality. The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-5347 |
Toner bottle cooling fan (FM35) rotation abnormality 1. The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. At this time, an error detection signal (24V cut off) is not detected. |
|
C-5348 |
Toner bottle cooling fan (FM35) rotation abnormality 2. When the print is started, the EM signal of FM35 turns ON. |
Main body: Scanner abnormality |
C-6101 |
Scanner motor (M27) movement time abnormality + 24V power abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is |
|
|
started. At this time, an error detection signal (24V cut off) of M27 is detected. |
|
C-6102 |
Scanner motor (M27) power abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected. |
|
C-6103 |
Scanner motor (M27) movement time abnormality. The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, an error detection signal (blowout of a fuse/24V cut off) of M27 is not detected. |
Main body: Fan abnormality |
C-6301 |
Scanner cooling fan (FM19) rotation abnormality + 24V power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (24V cut off) is detected. |
|
C-6302 |
Scanner cooling fan (FM19) power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected. |
|
C-6303 |
Scanner cooling fan (FM19) rotation abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected. |
Main body: Image processing abnormality |
C-6701 |
Filter coefficient abnormality. When processing images, a filter coefficient cannot be created normally. |
|
C-6702 |
Scanner FIFO abnormality. FIFO address abnormality for compression is indicated. |
|
C-6703 |
SVV length abnormality. After negation of SVV, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time. |
|
C-6704 |
Scanner time out. |
|
C-6705 |
Compression device access abnormality. When writing images, in spite of no resource provided, an inappropriate processing such as an access to the compression device is made. |
|
C-6706 |
SVV OFF abnormality. While in the image read, SVV does not turn OFF within a specified period of time and the preparation for scanning the next page cannot be started. |
|
C-6707 |
Shading correction abnormality (GA abnormality) |
|
C-6708 |
AOC/AGC adjustment level abnormality. AOC/AGC adjustment error occurs due to the abnormality related to the exposure lamp or the trouble of the read section. |
|
C-6709 |
Abnormality of the adjustment data by resolutions. The adjustment data evacuated by resolutions is not available. |
|
C-6710 |
Density conversion gamma curve creation abnormality. A density conversion gamma curve cannot be created normally. |
|
C-6717 |
N-in-1 page area abnormality. Due to an image area abnormality of the memory, images cannot be developed on the memory. |
|
C-6719 |
The original skew adjustment is too late. The scan operation starts before the original skew adjustment is terminated. |
|
C-6721 |
AGC retry. The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs. |
|
C-6801 |
Initial communication error between the image processing board (OACB) and the operation board /1 (OB1). An initial communication from the main body to the operation panel is not sent within 30 seconds after the power is turned ON. |
DF: DF abnormality |
C-8001 |
Sending error between the main body and DF. Although the main body sent out data according to the data transmission request by the DF, the same request is received again. |
|
C-8002 |
Reception error between the main body and DF. Checksum error or SRGA reception error is detected twice in succession while in the reception in serial communication. |
|
C-8003 |
Initial communication error between the main body and DF. When the main power switch (SW1) is ON, there is no response to the initial communication request from the main body to the DF even after a specified period of time elapses. |
|
C-8201 |
Tray up-down motor (M305) abnormality. |
|
C-8301 |
Cooling fan /Lt (FM301) and /Rt (FM302) abnormality |
|
C-8401 |
Original registration sensor /Lt (PS306) abnormality. |
|
C-8402 |
Original conveyance sensor (PS308) abnormality. |
|
C-8403 |
Original reverse sensor (PS309) abnormality |
|
C-8404 |
Non-volatile memory error |
|
C-8405 |
Reverse jam sensor (PS304) abnormality. |
|
C-8406 |
Original reverse-exit sensor (PS313) abnormality. |
|
C-8407 |
Original skew sensor /Fr (PS312) abnormality. |
|
C-8408 |
Original skew sensor /Rr (PS311) abnormality. |
|
C-8409 |
Original registration sensor /Rt (PS318) abnormality.(DF-615 only) |
|
C-8410 |
Centering sensor /Fr (PS320) abnormality. (DF-615 only) |
|
C-8411 |
Centering sensor /Rr (PS321) abnormality. (DF-615 only) |
|
C-8412 |
Multi feed detection boards /S (MFDBS) and /R (MFDBR) abnormality(DF-615 only) |
Main Body: IC Controller abnormality |
C-A001 |
Transfer error to the main body image memory |
|
C-A002 |
Hard disk /2 (HDD2) abnormality. |
|
C-A003 |
IC cooling fan (FM39) lock abnormality. |
|
C-A004 |
Unregulations IC error occurs. |
|
C-A005 |
Version abnormality between SSD (SSD) and hard disk /2 (HDD2). The SSD version is different from the version information in HDD2. |
|
C-A006 |
Hard disc /2 (HDD2) abnormality 1 while in the security ON. While in the security ON, the unlocking of the HDD results in a failure due to the mismatched password of the hard disk /2 (HDD2). |
|
C-A007 |
Hard disc /2 (HDD2) abnormality 2 while in the security ON. Unlocked HDD2 is detected while in the security ON. |
|
C-A008 |
Hard disk /2 (HDD2) is unformatted. An unformatted HDD2 is detected. |
|
C-A009 |
Controller memory abnormality. |
|
C-A101 |
Controller initial communication abnormality. |
Main body: Communication error |
C-C101 |
Initial communication error between the overall control board (OACB) and the printer control board (PRCB). No response is returned from PRCB even after a specified period of time after the main power switch (SW1) and the sub power switch (SW2) turn ON. Or ISW information is not written on PRCB. |
|
C-C102 |
Initial communication error between the overall control board (OACB) and the printer control board (PRCB). Communication error from PRCB is detected. Or transmission is not completed. |
|
C-C103 |
Communication error between the overall control board (OACB) and the operation board /1 (OB1). Communication error from OB1 is detected. Or transmission is not completed. |
|
C-C104* |
ISW write abnormality 1 of the printer control board. |
|
C-C105 |
ISW write abnormality 2 of the printer control board. |
|
C-C106 |
ISW time out error. No normal header is transmitted within a specified period of time after ISW is started. |
|
C-C107 |
ISW download abnormality. An error is detected while downloading ISW. |
|
C-C108 |
ISW write abnormality on the overall control board. An error is detected because ISW data cannot be written on the overall control board (OACB). |
FS: FS-532 ISW unwritten |
C-C109 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the FS firmware. |
LS: LS ISW unwritten |
C-C111 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (1st tandem). |
|
C-C112 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (2nd tandem). |
FD: FD ISW unwritten |
C-C113 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the FD firmware. |
SD: SD-506 ISW unwritten |
C-C114 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the SD firmware. |
PB: PB ISW unwritten |
C-C116 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the PB firmware. |
GP: GP-501 ISW unwritten |
C-C117 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the GP firmware. |
RU: RU-510 ISW unwritten |
C-C118 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU firmware. |
RU: RU-509 ISW unwritten |
C-C119 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU program. |
DF: Communication error |
C-C120 |
ISW write abnormality on DF. When the main power switch (SW1) is ON, unwritten area by the ISW is detected in the DF control program. |
LS: LS ISW unwritten |
C-C121 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (3rd tandem). |
FS: SD-510 ISW unwritten |
C-C124 |
When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the SD firmware. |
IC: Communication error |
C-C125 |
ISW write abnormality of controller. The firmware is not written on ICB or an error is detected during the ROM check. |
|
C-C130 |
Wrong serial number. The serial number for the different machine is specified. |
DF wrong installation |
C-C131 |
DF-615 is installed to PRO 951. Or, DF-615 is installed to PRESS1250/1052. |
Wrong installation of image processing board |
C-C132 |
The image processing board (IPB) used exclusively for PRESS1250/1250P/1052 is installed to PRO951. Or, IPB used exclusively for PRO951 is installed to PRESS1250/1250P/1052. |
Common API unmatched version |
C-C136 |
When the version differs between Common API for the overall control and IC controller. |
HDD: Communication error |
C-D001 |
Hard disk /1 (HDD1) initialization abnormality. HDD1 is defective, or the connector is poorly connected. |
|
C-D002 |
JOB_RAM storage abnormality. The JOB information cannot be stored on the hard disk /1 (HDD1). |
|
C-D003 |
Hard disk /1 (HDD1) periodic cleaning abnormality. While in a periodical cleaning, opening the rote to hard disk is not succeeded. |
|
C-D004 |
Hard disk /1 (HDD1) access defective. HDD1 is defective, or the connector is poorly connected. |
|
C-D010 |
Hard disk /1 (HDD1) overwrite erase execution. HDD1 overwrite erase is executed. |
Common API related HDD file crushed |
C-D080 |
The common API related HDD file on the hard disk / 1 (HDD1) is crushed |
HDD: Communication error |
C-E001 |
Message queue error. The message queue is insufficient or destroyed. |
|
C-E002 |
Message parameter value error. The parameter value is in excess of the permissible limits. |
|
C-E003 |
Source task error. The ID of the task that sends the message queue is undefined. |
|
C-E004 |
Receiving event error. The receiving event of the message is undefined. |
|
C-E005 |
Memory access abnormality. |
|
C-E006 |
Header readout address abnormality. |
|
C-E007 |
DRAM memory abnormality. An error is detected in the DRAM memory check at the start. |