Каталог продукции » Konica Minolta » Konica Minolta печатная техника » Bizhub Pro » bizhub PRO 951 » Код неисправности Bizhub PRESS 1250/1250P/1052/PRO 951 (MALFUNCTION CODE) 

Код неисправности Bizhub PRESS 1250/1250P/1052/PRO 951 (MALFUNCTION CODE)

bizhub PRO 951

Classification

Malfunction
code

Cause

Main body: Drive abnormality

C-0001

Main body drive serial input abnormality 1.

Within a specified period of time after the power ON, a serial data is not received between the printer control board (PRCB) and the main body drive board.

 

C-0002

Main body drive serial input abnormality 2.

Within a specified period of time after the power ON, a serial data is not received between the printer control board (PRCB) and the main body drive board.

 

C-0003

Main body drive serial input abnormality 3.

Within a specified period of time after the power ON, a serial data is not received between the printer control board (PRCB) and the main body drive board.

 

C-0004

Main body drive serial input abnormality4.

Within a specified period of time after the power ON, a serial data is not received between the printer control board (PRCB) and the main body drive board.

Main body:

Communication

error

C-0005

Drive communication reception error detection abnormality 3.

 

C-0006

Drive communication reception error detection abnormality 4.

 

C-0007

Drive communication reception error detection abnormality 5.

 

C-0008

Drive communication reception error detection abnormality 6.

 

C-0010

Drive communication reception error detection abnormality 2.

 

C-0011

Drive communication reception error detection abnormality 8.

 

C-0012

Drive communication reception error detection abnormality 9.

 

C-0020

ADU drive serial input abnormality 1.

In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received.

 

C-0021

ADU drive serial input abnormality 2.

In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received.

 

C-0022

ADU drive serial input abnormality 3.

In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received.

 

C-0023

Drive communication reception error detection abnormality 0.

 

C-0024

Drive communication reception error detection abnormality 7.

 

C-0025

Drive communication reception error detection abnormality 11.

Main body: Drive abnormality

C-0101

Paper feed motor (M4) speed abnormality.

An error detection signal is detected twice in succession within a specified period of time after M4 was turned ON.

PF: Drive

C-0103

1st tandem PF-703/706 paper feed motor (M1) speed abnormality.

An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON.

Main body:

Power

abnormality

C-0104

Abnormality of the vertical conveyance motor (M8) power in the printer control board (PRCB).

An error detection signal (blowout of ICP) of M8 is detected when M8 is turned ON.

PF: Power abnormality

C-0105

Abnormality of the PF exit conveyance motor (M2) power in the PF drive board (PFUDB) of the 1st tandem PF-706.

An error detection signal (blowout of ICP) of M2 is detected when M2 is turned ON.

PF: Drive

C-0106

2nd tandem PF-703/706 paper feed motor speed abnormality.

An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON.

PF: Power abnormality

C-0107

Abnormality of the PF exit conveyance motor (M2) power in the PF drive board (PFUDB) of the 2nd tandem PF-706.

An error detection signal (blowout of ICP) of M2 is detected when M2 is turned ON.

 

C-0108

Abnormality of the PF conveyance motor (M3) power in the PF drive board (PFUDB) of the 1st tandem PF-703.

An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON.

 

C-0109

Abnormality of the PF conveyance motor (M3) power in the PF drive board (PFUDB) of the 2nd tandem PF-703.

An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON.

Main body:

Power

abnormality

C-0110

Abnormality of the registration section motor IC in the ADU drive board (ADUDB).

The error detection signals of the ADU conveyance motor /2 (M16), the registration motor (M17) and the loop motor (M18) are detected after the print is started.

 

C-0111

Abnormality of the duplex section motor IC in the ADU drive board (ADUDB).

The error detection signals of the ADU reverse motor (M12), the reverse/exit motor (M13), the ADU accelerate motor (M14) and the ADU conveyance motor /1 (M15) are detected after the print is started.

 

C-0112

Vertical conveyance motor IC abnormality in the printer control board (PRCB)

An error detection signal of vertical conveyance motor (M8) is detected after the print starts.

 

C-0113

Abnormality 1 of the SD/ CL_24V power for the printer control board (PRCB) tray.

At the start, the error detection signals of the PRCB tray solenoid/clutch ICP blowout and 24V cut off are detected.

 

C-0114

Abnormality 2 of the SD/ CL_24V power for the printer control board (PRCB) tray.

When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start.

 

C-0115

Abnormality 1 of the SD/ CL_24V power for the printer control board (PRCB) vertical conveyance.

At the start, the error detection signals of the PRCB vertical conveyance solenoid/clutch ICP blowout and 24V cut off are detected.

 

C-0116

Abnormality 2 of the SD/ CL_24V power for the printer control board (PRCB) tray.

When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start.

PF: Power abnormality

C-0118

Abnormality of the power for the PF drive board

 

 

(PFUDB) SD/CL of the PF-703/706.

At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.

Main body: Drive

C-0119

The transfer belt cleaning motor (M5) speed abnormality.

The M5EM error detection signal is detected twice in succession within a specified period of time after M5 was turned ON.

 

C-0120

Paper exit conveyance motor (M31) speed abnormality.

The M31EM error detection signal is detected twice in succession within a specified period of time after M31 was turned ON.

 

C-0121

Paper exit motor (M20) speed abnormality.

The M20EM error detection signal is detected twice in succession within a specified period of time after M20 was turned ON.

PF: Power abnormality

C-0130

PF-703 coupling conveyance motor /1 (M4) power abnormality.

An error detection signal (blowout of ICP) of M4 is detected when M4 is turned ON.

 

C-0131

PF-703 coupling conveyance motor /2 and / 3 (M5 and M6) power abnormality.

An error detection signal (blowout of ICP) of M5 and M6 is detected when M5 and M6 are turned ON.

 

C-0132

Abnormality of the power for the PF drive board (PFUDB) SD/CL of the 2nd tandem PF-703/706.

At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.

PF: Drive

C-0133

1st tandem PF-703 paper feed belt motor (M2) speed abnormality.

An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON.

 

C-0134

2nd tandem PF-703 paper feed belt motor (M2) speed abnormality.

An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON.

PI-PFU: Drive

C-0140

Paper feed motor speed abnormality of PI-PFU (PF-703) tandem PF.

 

 

An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON.

PI-PFU: Power abnormality

C-0141

PI-PFU (PF-703) PF exit conveyance motor (M3) power abnormality.

An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON.

 

C-0142

PI-PFU (PF-703) coupling conveyance motor /1 (M4) power abnormality.

An error detection signal (blowout of ICP) of M4 is detected when M4 is turned ON.

 

C-0143

PI-PFU (PF-703) coupling conveyance motor /2 and / 3 (M5 and M6) power abnormality.

An error detection signal (blowout of ICP) of M5 and M6 is detected when M5 and M6 are turned ON.

 

C-0144

PI-PFU (PF-703) SD/CL power abnormality.

At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.

PI-PFU: Drive

C-0145

PI-PFU (PF-703) paper feed belt motor (M2) speed abnormality.

An error detection signal is detected twice in succession within a specified period of time after M2 was turned ON.

LU

C-0150

An abnormal speed signal of the paper feed motor (M101) is checked.

An error detection signal is detected twice in succession a specified period of time after M101 was turned ON (the first signal is ignored).

 

C-0151

The locking of the paper lift motor (M100) is detected. When M100 is ON, an error detection signal of the M100 is detected in succession for 1 second.

LU: Power

source

abnormality

C-0152

Abnormality of the paper lift motor (M100) power in the LU drive board (LUDB).

An error detection signal (blowout of ICP) of M100 is detected.

 

C-0153

Abnormality of the solenoid and clutch power in the LU drive board (LUDB).

An error detection signals (blowout of ICP) of the pick up solenoid (SD100), the paper feed clutch (CL101), and the preregistration clutch (CL102) are detected after the print is started.

Main body: Trayl

C-0201

Trayl: up abnormality When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the tray lift-up motor /1 (M25) turns ON for lifting operation. At this time, an error detection signal (24V cut off) is detected.

 

C-0203

Tray1 up abnormality 2. When the upper limit sensor /1 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the tray lift-up motor /1 (M25) turns ON for lifting operation. At this time, an error detection signal is not detected.

 

C-0204

The locking of the tray lift- up motor /1 (M25) is detected.

An error detection signal of M25 is detected while M25 is ON.

Main body: Tray2

C-0205

Tray2 up abnormality 1. When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the tray lift-up motor /2 (M34) turns ON for lifting operation. At this time, an error detection signal (24V cut off) is detected.

 

C-0207

Tray /2 up abnormality 2. When the upper limit sensor /2 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the tray lift-up motor /2 (M34) turns ON for lifting operation. At this time, an error detection signal is not detected.

 

C-0208

The locking of the tray lift- up motor /2 (M34) is detected.

When M34 is ON, an error detection signal of the M34 is detected.

PF: Tray3

C-0222

1st tandem PF-703/706 upper tray up abnormality. PF-703: When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20 seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and / Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting.

PF-706: When the upper limit sensor /1 (PS2) is OFF, PS2 does not turn ON within 20 seconds after the paper lift motor /1 (M42) turns ON for the lifting operation.

 

C-0223

The locking of the paper lift motor /1 of the 1st tandem PF-703/706 upper tray (M7: PF-703, M42:

PF-706) is detected.

When M7 and M42 are ON, error detection signals of the M7 and M42 are detected.

PF: Tray4

C-0226

1st tandem PF-703/706 middle tray up abnormality. PF-703: When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20 seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and / Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting.

PF-706: When the upper limit sensor /2 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the paper lift motor /2 (M43) turns ON for the lifting operation.

 

C-0227

The locking of the paper lift motor /2 of the 1st tandem PF-703/706 middle tray (M8: PF-703, M43:

PF-706) is detected.

When M8 and M43 are ON, error detection signals of the M8 and M43 are detected.

PF: Tray5

C-0230

1st tandem PF-703/706 lower tray up abnormality. PF-703: When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20 seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and / Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting.

PF-706: When the upper limit sensor /3 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for the lifting operation.

 

C-0231

The locking of the paper lift motor /3 of the 1st tandem PF-703/706 lower tray (M9: PF-703, M44:

PF-706) is detected.

When M9 and M44 are ON, error detection signals of the M9 and M44 are detected.

PF: Tray6

C-0240

2nd tandem PF-703/706 upper tray up abnormality. PF-703: When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20 seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and / Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting.

PF-706: When the upper limit sensor /1 (PS2) is OFF, PS2 does not turn ON within 20 seconds after the paper lift motor /1 (M42) turns ON for the lifting operation.

 

C-0241

The locking of the paper lift motor /1 of the 2nd tandem PF-703/706 upper tray (M7: PF-703, M42:

PF-706) is detected.

When M7 and M42 are ON, error detection signals of the M7 and M42 are detected.

PF: Tray7

C-0242

2nd tandem PF-703/706 middle tray up abnormality. PF-703: When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20 seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and / Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting.

PF-706: When the upper limit sensor /2 (PS6) is OFF, PS6 does not turn ON within 20 seconds after the paper lift motor /2 (M43) turns ON for the lifting operation.

 

C-0243

The locking of the paper lift motor /2 of the 2nd tandem PF-703/706 middle tray (M8: PF-703, M43:

PF-706) is detected.

When M8 and M43 are ON, error detection signals of the M8 and M43 are detected.

PF: Tray8

C-0244

2nd tandem PF-703/706 lower tray up abnormality. PF-703: When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20 seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and / Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting.

PF-706: When the upper limit sensor /3 (PS10) is OFF, PS10 does not turn ON within 20 seconds after the paper lift motor /3 (M44) turns ON for the lifting operation.

 

C-0245

The locking of the paper lift motor /3 of the 2nd tandem PF-703/706 lower tray (M9: PF-703, M44:

PF-706) is detected.

When M9 and M44 are ON, error detection signals of the M9 and M44 are detected.

PI-PFU: PI Tray1

C-0250

PI-PFU (PF-703) upper tray up abnormality.

When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20 seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and / Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting.

 

C-0251

The locking of the upper tray paper lift motor /1 (M7) is detected.

When M7 is ON, an error detection signal of the M7 is detected.

PI-PFU: PI Tray2

C-0252

PI-PFU (PF-703) middle tray up abnormality.

When the upper limit sensor /2 (PS9) is OFF, PS9 does not turn ON within 20 seconds after the paper lift motor /2 (M8) turns ON for lifting operation. Or, the paper suction sensor /Fr2 and / Rr2 (PS27 and PS28) turn ON before PS9 turns ON while in tray lifting.

 

C-0253

The locking of the upper tray paper lift motor /2 (M8) is detected.

When M8 is ON, an error detection signal of the M8 is detected.

PI-PFU: PI Tray3

C-0254

PI-PFU (PF-703) lower tray up abnormality.

When the upper limit sensor /3 (PS13) is OFF, PS13 does not turn ON within 20 seconds after the paper lift motor /3 (M9) turns ON for lifting operation. Or, the paper suction sensor /Fr3 and / Rr3 (PS29 and PS30) turn ON before PS13 turns ON while in tray lifting.

 

C-0255

The locking of the upper tray paper lift motor /3 (M9) is detected.

When M9 is ON, an error detection signal of the M9 is detected.

PF: Tray3

C-0261

1st tandem PF-703 shutter motor /1 (M10) operation time abnormality 1.

The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0262

1st tandem PF-703 shutter motor /1 (M10) operation time abnormality 2.

The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PF: Tray4

C-0263

1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 1.

The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0264

1st tandem PF-703 shutter motor /2 (M11) operation time abnormality 2.

The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PF: Tray5

C-0265

1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 1.

The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0266

1st tandem PF-703 shutter motor /3 (M12) operation time abnormality 2.

The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PF: Tray6

C-0271

2nd tandem PF-703 shutter motor /1 (M10) operation time abnormality 1.

The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0272

2nd tandem PF-703 shutter motor /1 (M10) operation time abnormality 2.

The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PF: Tray7

C-0273

2nd tandem PF-703 shutter motor /2 (M11) operation time abnormality 1.

The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0274

2nd tandem PF-703 shutter motor /2 (M11) operation time abnormality 2.

The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PF: Tray8

C-0275

2nd tandem PF-703 shutter motor /3 (M12) operation time abnormality 1.

The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0276

2nd tandem PF-703 shutter motor /3 (M12) operation time abnormality 2.

The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PI-PFU: PI Tray1

C-0281

PI-PFU (PF-703)shutter motor /1 (M10) operation time abnormality 1.

The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0282

PI-PFU (PF-703)shutter motor /1 (M10) operation time abnormality 2.

The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PI-PFU: PI Tray2

C-0283

PI-PFU (PF-703)shutter motor /2 (M11) operation time abnormality 1.

The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0284

PI-PFU (PF-703)shutter motor /2 (M11) operation time abnormality 2.

The M11EM error detection signal is detected twice in succession within a specified period of time after M11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PI-PFU: PI Tray3

C-0285

PI-PFU (PF-703)shutter motor /3 (M12) operation time abnormality 1.

The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of fan ICP) is not detected.

 

C-0286

PI-PFU (PF-703)shutter motor /3 (M12) operation time abnormality 2.

The M12EM error detection signal is detected twice in succession within a specified period of time after M12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

Main body: Fan abnormality

C-0304

Paper exit cooling fan /Up (FM4) rotation abnormality + 24V power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-0306

Paper exit cooling fan /Up (FM4) rotation abnormality. The FM4 EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, error detection signal (24V cut off) is not detected.

 

C-0307

Paper exit cooling fan /Lw1 (FM10) rotation abnormality + 24V power abnormality.

The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-0309

Paper exit cooling fan /Lw1 (FM10) rotation abnormality.

The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. In addition, error detection signal (24 V cut off) is not detected.

 

C-0310

Paper exit cooling fan /Lw2 (FM28) rotation abnormality + 24V power abnormality.

The FM28EM error detection signal is detected twice in succession within a specified period of time after FM28 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-0312

Paper exit cooling fan /Lw2 (FM28) rotation abnormality.

The FM28 EM error detection signal is detected twice in succession within a specified period of time after FM28 was turned ON. However, error detection signal (24V cut off) is not detected.

 

C-0320

Paper feed assist fan /Rr1 (FM20) rotation abnormality + 24V power abnormality.

The FM20 EM error detection signal is detected twice in succession within a specified period of time after FM20 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

С-0З22

Paper feed assist fan /Rr1 (FM20) rotation abnormality.

The FM20 EM error detection signal is detected twice in succession within a specified period of time after FM20 was turned ON. However, error detection signal (24V cut off) is not detected.

 

С-0З2З

Paper feed assist fan /Fr1 (FM21) rotation abnormality + 24V power abnormality.

The FM21 EM error detection signal is detected twice in succession within a specified period of time after FM21 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

С-0З25

Paper feed assist fan /Fr1 (FM21) rotation abnormality.

The FM21 EM error detection signal is detected twice in succession within a specified period of time after FM21 was turned ON. However, error detection signal (24V cut off) is not detected.

 

C-0326

Paper feed assist fan /Rr2 (FM24) rotation abnormality + 24V power abnormality.

The FM24 EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-0328

Paper feed assist fan /Rr2 (FM24) rotation abnormality.

The FM24 EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, error detection signal (24V cut off) is not detected.

 

С-0З29

Paper feed assist fan /Fr2 (FM23) rotation abnormality + 24V power abnormality.

The FM23 EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

С-0ЗЗ1

Paper feed assist fan /Fr2 (FM23) rotation abnormality.

The FM23 EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, error detection signal (24V cut off) is not detected.

PF : fan abnormality

С-0З41

1st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0342

1st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

С-0З44

1st tandem PF-703/706 paper feed assist fan /Rr1 (FM2) power abnormality. The EM error detection signal of FM2 is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0345

1st tandem PF-703/706 paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0347

1st tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) power abnormality.

The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0348

1st tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) rotation abnormality.

The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0350

1st tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) power abnormality.

The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0351

1st tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) rotation abnormality.

The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

С-0З5З

1st tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) power abnormality.

The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

С-0З54

1st tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) rotation abnormality.

The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0356

1st tandem PF-703/706 paper feed assist fan /Rr3 (FM10: PF-703, FM6: PF-706) power abnormality.

The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0357

1st tandem PF-703/706 paper feed assist fan /Rr3 (FM10: PF-703, FM6: PF-706) rotation abnormality.

The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0359

1st tandem PF-703/706 cooling fan power abnormality.

PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PF-706: The FM7 EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0360

1st tandem PF-703/706 cooling fan rotation abnormality 1.

PF-703: The FM19 EM and FM20 EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected.

PF-706: The FM20 EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan (FM7) turns ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0361

1st tandem PF-703 cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0370

2st tandem PF-703/706 paper feed assist fan /Fr1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

С-0З71

2nd tandem PF-703/706 paper feed assist fan /Fr1 (FM1) rotation abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

С-0З72

Paper feed assist fan /Fr1 (FM2: PF-703)

 

С-0З7З

2nd tandem PF-703/706 paper feed assist fan /Rr1 (FM2) rotation abnormality. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0374

2nd tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) power abnormality.

The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0375

2nd tandem PF-703/706 paper feed assist fan /Fr2 (FM5: PF-703, FM3: PF-706) rotation abnormality.

The FM5 EM and FM3 EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM3 were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0376

2nd tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) power abnormality.

The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

С-0З77

2nd tandem PF-703/706 paper feed assist fan /Rr2 (FM6: PF-703, FM4: PF-706) rotation abnormality.

The FM6 EM and FM4 EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM4 were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

С-0З78

2nd tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) power abnormality.

The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

С-0З79

2nd tandem PF-703/706 paper feed assist fan /Fr3 (FM9: PF-703, FM5: PF-706) rotation abnormality.

The FM9 EM and FM5 EM error detection signals are detected twice in succession within a specified period of time after FM9 and FM5 were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0380

2nd tandem PF-703/706 paper feed assist fan /Rr3 (FM10: PF-703, FM6: PF-706) power abnormality.

The FM10 EM and FM6 EM error detection signals are detected twice in succession within a specified period of time after FM10 and FM6 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0381

2nd tandem PF-703/706 paper feed assist fan /Rr3 (FM10 PF-703, FM6: PF-706) rotation abnormality.

The FM6EM and FM10EM error detection signals are detected twice in succession within a specified period of time after FM6 and FM10 were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0382

2nd tandem PF-703/706 cooling fan power abnormality.

PF-703: The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

PF-706: The FM7 EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan (FM7) was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0383

2nd tandem PF-703/706 cooling fan rotation abnormality 1.

PF-703: The FM19 EM and FM20 EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected.

PF-706: The FM20 EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan (FM7) turns ON. However, an error detection signal (blowout of ICP) is not detected.

 

С-0З84

2nd tandem PF-703 cooling fan rotation abnormality 2.

The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.

PI-PFU : Fan abnormality

С-0З85

PI-PFU (PF-703) paper feed assist fan /Fr1 (FM1) power abnormality.

The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

С-0З86

PI-PFU (PF-703) paper feed assist fan /Fr1 (FM1) rotation abnormality.

The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0387

PI-PFU (PF-703) paper feed assist fan /Rr1 (FM2) power abnormality.

The EM error detection signal of FM2 is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

С-0З88

PI-PFU (PF-703) paper feed assist fan /Rr1 (FM2) rotation abnormality.

The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0389

PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) power abnormality.

The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0390

PI-PFU (PF-703) paper feed assist fan /Fr2 (FM5) rotation abnormality.

The FM5EM error detection signal is detected twice in succession within a specified period of time after FM5 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0391

PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) power abnormality.

The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0392

PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) rotation abnormality.

The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0393

PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) power abnormality.

The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0394

PI-PFU (PF-703) paper feed assist fan /Fr3 (FM9) rotation abnormality.

The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0395

PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) power abnormality. The EM error detection signal of FM10 is detected twice in succession within a specified period of time after FM10 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0396

PI-PFU (PF-703) paper feed assist fan /Rr3 (FM10) rotation abnormality.

The FM10EM error detection signal is detected twice in succession within a specified period of time after FM10 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0397

PI-PFU (PF-703) cooling fan power abnormality. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0398

PI-PFU (PF-703) cooling fan rotation abnormality 1. The FM19EM and FM20EM error detection signals are detected twice in succession within a specified period of time after the PF cooling fan /1 and /2 (FM19 and FM20) were turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0399

PI-PFU (PF-703) cooling fan rotation abnormality 2. The FM21EM error detection signal is detected twice in succession within a specified period of time after the PF cooling fan /3 (FM21) was turned ON with the front door closed. At this time, an error detection signal (blowout of ICP) is detected.

Main

body:Power

abnormality

C-0403

12V power abnormality in the printer control board (PRCB).

An error detection signal of the 12V in PFDB (blowout of ICP) is detected.

 

C-0404

5V power abnormality in the printer control board (PRCB).

An error detection signal of the 5V in PRCB (blowout of ICP) is detected.

 

C-0410

12V power abnormality in the ADU drive board (ADUDB).

An error detection signal of the ADUDB (blowout of ICP) is detected.

 

C-0411

ADU drive board (ADUDB) power abnormality 1.

An error detection signal (blowout of ICP) of the transfer paper correction sensor (PS4), transfer exposure lamp (L4) or SD is detected. At this time, an error detection signal (24V cut off) is detected.

 

C-0412

ADU drive board (ADUDB) power abnormality 2.

An error detection signal (blowout of ICP) of the transfer paper correction sensor (PS4), transfer exposure lamp (L4) or SD is detected. However, an error detection signal (24V cut off) is not detected.

 

C-0413

Interlock power abnormality of the ADU drive board (ADUDB).

An error signal of the 24V interlock power is detected in the door detection closed status.

Main body: Centering sensor abnormality

C-0414

During the centering censor (PS4) is ON, the centering data does not sent from the ADU drive board though more than 5 sheets are processed in succession.

PF: PF power

source

abnormality

C-0420

PF drive board (PFUDB: PF-703/706)

 

C-0421

Abnormality of the 12V power for the PF drive board (PFUDB) of the 2nd tandem PF-703/706.

An error detection signal of the PFUDB (blowout of 12V ICP) is detected.

 

C-0422

Abnormality of the 24V power for the PF drive board (PFUDB) of the 1st tandem PF-703/706. While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.

 

C-0423

Abnormality of the 24V power for the PF drive board (PFUDB) of the 2nd tandem PF-703/706.

While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.

PI-PFU: Power abnormality

C-0424

Abnormality of the 12V power for the PF drive board (PFUDB) of PI-PFU (PF-703).

An error detection signal of the PFUDB (blowout of 12V ICP) is detected.

 

C-0425

Abnormality of the 24V power for the PF drive board (PFUDB) of PI-PFU (PF-703).

While in printing, an error detection signal (24V power DOWN) of the PFUDB is detected.

PF: PF power

source

abnormality

C-0501

1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality.

The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0502

1st tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality.

The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0503

1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality.

The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0504

1st tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality.

The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0505

1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality.

The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0506

1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality.

The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0507

1st tandem PF-703 paper leading edge separation fan /Rr1 (FM4) power abnormality.

The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0508

1st tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality.

The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0509

1st tandem PF-703 paper leading edge separation fan /Rr2 (FM8) power abnormality.

The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0510

1st tandem PF-703 paper leading edge separation fan /Rr2 (FM8) rotation abnormality.

The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0511

1st tandem PF-703 paper leading edge separation fan /Rr3 (FM12) power abnormality.

The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0512

1st tandem PF-703 paper leading edge separation fan /Rr3 (FM12) rotation abnormality.

The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0513

1st tandem PF-703 paper suction fan /1 (FM13) power abnormality.

The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0514

1st tandem PF-703 paper suction fan /1 (FM13) rotation abnormality.

The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0515

1st tandem PF-703 paper suction fan /3 (FM15) power abnormality.

The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0516

1st tandem PF-703 paper suction fan /3 (FM15) rotation abnormality.

The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0517

1st tandem PF-703 paper suction fan /5 (FM17) power abnormality.

The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0518

1st tandem PF-703 paper suction fan /5 (FM17) rotation abnormality.

The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0519

1st tandem PF-703 paper suction fan /1 (FM14) power abnormality.

The EM error detection signal of FM14 is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0520

1st tandem PF-703 paper suction fan /1 (FM14) rotation abnormality.

The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0521

1st tandem PF-703 paper suction fan /3 (FM16) power abnormality.

The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0522

1st tandem PF-703 paper suction fan /3 (FM16) rotation abnormality.

The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0523

1st tandem PF-703 paper suction fan /5 (FM18) power abnormality.

The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0524

1st tandem PF-703 paper suction fan /5 (FM18) rotation abnormality.

The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0525

2nd tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality.

The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0526

2nd tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality.

The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0527

2nd tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality.

The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0528

2nd tandem PF-703 paper leading edge separation fan /Fr2 (FM7) rotation abnormality.

The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0529

2nd tandem PF-703 paper leading edge separation fan /Fr3 (FM11) power abnormality.

The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0530

2nd tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality.

The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0531

2nd tandem PF-703 paper leading edge separation fan /Rr1 (FM4) power abnormality.

The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0532

2nd tandem PF-703 paper leading edge separation fan /Rr1 (FM4) rotation abnormality.

The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0533

2nd tandem PF-703 paper leading edge separation fan /Rr2 (FM8) power abnormality.

The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0534

2nd tandem PF-703 paper leading edge separation fan /Rr2 (FM8) rotation abnormality.

The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0535

2nd tandem PF-703 paper leading edge separation fan /Rr3 (FM12) power abnormality.

The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0536

2nd tandem PF-703 paper leading edge separation fan /Rr3 (FM12) rotation abnormality.

The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0537

2nd tandem PF-703 paper suction fan /1 (FM13) power abnormality.

The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0538

2nd tandem PF-703 paper suction fan /1 (FM13) rotation abnormality.

The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0539

2nd tandem PF-703 paper suction fan /3 (FM15) power abnormality.

The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0540

2nd tandem PF-703 paper suction fan /3 (FM15) rotation abnormality.

The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0541

2nd tandem PF-703 paper suction fan /5 (FM17) power abnormality.

The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0542

2nd tandem PF-703 paper suction fan /5 (FM17) rotation abnormality.

The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0543

2nd tandem PF-703 paper suction fan /1 (FM14) power abnormality.

The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0544

2nd tandem PF-703 paper suction fan /1 (FM14) rotation abnormality.

The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0545

2nd tandem PF-703 paper suction fan /3 (FM16) power abnormality.

The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0546

2nd tandem PF-703 paper suction fan /3 (FM16) rotation abnormality.

The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0547

2nd tandem PF-703 paper suction fan /5 (FM18) power abnormality.

The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0548

2nd tandem PF-703 paper suction fan /5 (FM18) rotation abnormality.

The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0561

PI-PFU (PF-703) paper leading edge separation fan /Fr1 (FM3) power abnormality.

The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0562

PI-PFU (PF-703) paper leading edge separation fan /Fr1 (FM3) rotation abnormality.

The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0563

PI-PFU (PF-703) paper leading edge separation fan /Fr2 (FM7) power abnormality.

The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0564

PI-PFU (PF-703) paper leading edge separation fan /Fr2 (FM7) rotation abnormality.

The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0565

PI-PFU (PF-703) paper leading edge separation fan /Fr3 (FM11) power abnormality.

The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0566

PI-PFU (PF-703) paper leading edge separation fan /Fr3 (FM11) rotation abnormality.

The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0567

PI-PFU (PF-703) paper leading edge separation fan /Rr1 (FM4) power abnormality.

The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0568

PI-PFU (PF-703) paper leading edge separation fan /Rr1 (FM4) rotation abnormality.

The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0569

PI-PFU (PF-703) paper leading edge separation fan /Rr2 (FM8) power abnormality.

The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0570

PI-PFU (PF-703) paper leading edge separation fan /Rr2 (FM8) rotation abnormality.

The FM8EM error detection signal is detected twice in succession within a specified period of time after FM8 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0571

PI-PFU (PF-703) paper leading edge separation fan /Rr3 (FM12) power abnormality.

The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0572

PI-PFU (PF-703) paper leading edge separation fan /Rr3 (FM12) rotation abnormality.

The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0573

PI-PFU (PF-703) paper suction fan /1 (FM13) power abnormality.

The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0574

PI-PFU (PF-703) paper suction fan /1 (FM13) rotation abnormality.

The FM13EM error detection signal is detected twice in succession within a specified period of time after FM13 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0575

PI-PFU (PF-703) paper suction fan /3 (FM15) power abnormality.

The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0576

PI-PFU (PF-703) paper suction fan /3 (FM15) rotation abnormality.

The FM15EM error detection signal is detected twice in succession within a specified period of time after FM15 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0577

PI-PFU (PF-703) paper suction fan /5 (FM17) power abnormality.

The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0578

PI-PFU (PF-703) paper suction fan /5 (FM17) rotation abnormality.

The FM17EM error detection signal is detected twice in succession within a specified period of time after FM17 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0579

PI-PFU (PF-703) paper suction fan /1 (FM14) power abnormality.

The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0580

PI-PFU (PF-703) paper suction fan /1 (FM14) rotation abnormality.

The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0581

PI-PFU (PF-703) paper suction fan /3 (FM16) power abnormality.

The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0582

PI-PFU (PF-703) paper suction fan /3 (FM16) rotation abnormality.

The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0583

PI-PFU (PF-703) paper suction fan /5 (FM18) power abnormality.

The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.

 

C-0584

PI-PFU (PF-703) paper suction fan /5 (FM18) rotation abnormality.

The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0601

1st tandem PF-703 dehumidifier fan /Rt1 (FM22) rotation abnormality.

The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0602

PI-PFU (PF-703) dehumidifier fan /Lt1 (FM23) rotation abnormality.

The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0603

1st tandem PF-703 dehumidifier fan /Rt2 (FM24) rotation abnormality.

The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0604

1st tandem PF-703 dehumidifier fan /Lt2 (FM25) rotation abnormality.

The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0605

1st tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality.

The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0606

1st tandem PF-703 dehumidifier fan /Lt3 (FM27) rotation abnormality.

The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0611

2nd tandem PF-703 dehumidifier fan /Rt1 (FM22) rotation abnormality.

The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0612

2nd tandem PF-703 dehumidifier fan /Lt1 (FM23) rotation abnormality.

The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0613

2nd tandem PF-703 dehumidifier fan /Rt2 (FM24) rotation abnormality.

The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0614

2nd tandem PF-703 dehumidifier fan /Lt2 (FM25) rotation abnormality.

The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0615

2nd tandem PF-703 dehumidifier fan /Rt3 (FM26) rotation abnormality.

The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0616

2nd tandem PF-703 dehumidifier fan /Lt3 (FM27) rotation abnormality.

The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0621

PI-PFU (PF-703) dehumidifier fan /Rt1 (FM22) rotation abnormality.

The FM22EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0622

PI-PFU (PF-703) dehumidifier fan /Lt1 (FM23) rotation abnormality.

The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

С-062З

PI-PFU (PF-703) dehumidifier fan /Rt2 (FM24) rotation abnormality.

The FM24EM error detection signal is detected twice in succession within a specified period of time after FM24 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0624

PI-PFU (PF-703) dehumidifier fan /Lt2 (FM25) rotation abnormality.

The FM25EM error detection signal is detected twice in succession within a specified period of time after FM25 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0625

PI-PFU (PF-703) dehumidifier fan /Rt3 (FM26) rotation abnormality.

The FM26EM error detection signal is detected twice in succession within a specified period of time after FM26 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-0626

PI-PFU (PF-703) dehumidifier fan /Lt3 (FM27) rotation abnormality.

The FM27EM error detection signal is detected twice in succession within a specified period of time after FM27 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

PF: Heater high

temperature

abnormality

C-0631

1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal.

 

C-0632

1st tandem PF-703 dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal.

 

C-0633

1st tandem PF-703 dehumidification heater /3 (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal.

 

C-0634

1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C.

 

C-0635

1st tandem PF-703 dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C.

 

C-0636

1st tandem PF-703 dehumidification heater /3 (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C.

PF: Heater low

temperature

abnormality

C-0637

1st tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality.

The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

 

C-0638

1st tandem PF-703 dehumidification heater /2 (HTR2) low temperature software abnormality.

The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

 

C-0639

1st tandem PF-703 dehumidification heater /3 (HTR3) low temperature software abnormality.

The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

PF: Heater temperature rise abnormality

C-0640

1st tandem PF-703 dehumidification heater /1 (HTR1) temperature rise abnormality.

The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

 

C-0641

1st tandem PF-703 dehumidification heater /2 (HTR2) temperature rise abnormality.

The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

 

C-0642

1st tandem PF-703 dehumidification heater /3 (HTR3) temperature rise abnormality.

The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

PF: Heater high

temperature

abnormality

C-0651

2nd tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal.

 

C-0652

2nd tandem PF-703 dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal.

 

C-0653

2nd tandem PF-703 dehumidification heater /3 (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal.

 

C-0654

2nd tandem PF-703 dehumidification heater /1 (HTR1) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C.

 

C-0655

2nd tandem PF-703 dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C.

 

C-0656

2nd tandem PF-703 dehumidification heater /3 (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C.

PF: Heater low

temperature

abnormality

C-0657

2nd tandem PF-703 dehumidification heater /1 (HTR1) low temperature hardware abnormality.

The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

 

C-0658

2nd tandem PF-703 dehumidification heater /2 (HTR2) low temperature software abnormality.

The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

 

C-0659

2nd tandem PF-703 dehumidification heater /3 (HTR3) low temperature software abnormality.

The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

PF: Heater temperature rise abnormality

C-0660

2nd tandem PF-703 dehumidification heater /1 (HTR1) temperature rise abnormality.

The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

 

C-0661

2nd tandem PF-703 dehumidification heater /2 (HTR2) temperature rise abnormality.

The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

 

C-0662

2nd tandem PF-703 dehumidification heater /3 (HTR3) temperature rise abnormality.

The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

PF: Heater high

temperature

abnormality

C-0671

PI-PFU (PF-ГОЗ) dehumidification heater /1 (HTR) high temperature hardware abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects a heater abnormality signal.

 

C-0672

PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature hardware abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects a heater abnormality signal.

 

C-0673

PI-PFU (PF-ГОЗ) dehumidification heater /З (HTR3) high temperature hardware abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects a heater abnormality signal.

 

C-0674

PI-PFU (PF-ГОЗ) dehumidification heater /1 (HTR) high temperature software abnormality. After turned ON, the temperature sensor /5 (TEMS/5) detects the heater temperature exceeding 105°C.

 

C-0675

PI-PFU (PF-703) dehumidification heater /2 (HTR2) high temperature software abnormality. After turned ON, the temperature sensor /6 (TEMS/6) detects the heater temperature exceeding 105°C.

 

C-0676

PI-PFU (PF-703) dehumidification heater /З (HTR3) high temperature software abnormality. After turned ON, the temperature sensor /7 (TEMS/7) detects the heater temperature exceeding 105°C.

PF: Heater low

temperature

abnormality

C-0677

PI-PFU (PF-ГОЗ) dehumidification heater /1 (HTR1) low temperature software abnormality.

The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

 

C-0678

PI-PFU (PF-ГОЗ) dehumidification heater /2 (HTR2) low temperature software abnormality.

The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

 

C-0679

PI-PFU (PF-703) dehumidification heater /3 (HTR3) low temperature software abnormality.

The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 0°C a specified period of time after the heater is turned ON.

PF: Heater temperature rise abnormality

C-0680

PI-PFU (PF-703) dehumidification heater /1 (HTR1) temperature rise abnormality.

The temperature sensor /5 (TEMS/5) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

 

C-0681

PI-PFU (PF-703) dehumidification heater /2 (HTR2) temperature rise abnormality.

The temperature sensor /6 (TEMS/6) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

 

C-0682

PI-PFU (PF-703) dehumidification heater /3 (HTR3) temperature rise abnormality.

The temperature sensor /7 (TEMS/7) detects the heater temperature lower than 40°C a specified period of time after the heater is turned ON.

Finishing:

Communication

error

C-1001

Serial communication error between the main body and the finishing option.

FS: FS-532 abnormality

C-1005

Communication error.

FD: FD abnormality

C-1006

Communication error.

SD: SD-506 abnormality

C-1007

Communication error.

PB: PB abnormality

C-1009

Communication error between Main CPU in the PB control board (PBCB) and Sub CPU1.

 

C-1010

Communication error between Main CPU in the PB control board (PBCB) and Sub CPU2.

PB control board (PBCB)

C-1011

Paper feed error between the main body and PB.

GP : GP-501 abnormality

C-1012

Communication

abnormality.

RU: RU-509 abnormality

C-1013

Communication error.

RU: RU-510 abnormality

C-1014

Communication error.

FS: FS-532 abnormality

C-1102

The tray up down motor (M11) does not turn OFF even when a specified period of time elapses after it starts operations. Or, it operates for more than the allowed time at a speed out of the specified one.

 

C-1103

The stacker alignment home sensor (PS12) does not turn ON within a specified period of time after the home position search operation of the stacker alignment motor (M9) starts.

 

C-1105

The paper exit opening unit does not get to the specified opening position within a specified period of time after the paper exit opening motor (M10) starts operations.

 

C-1106

The stapler movement home sensor (PS22) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M14) starts.

 

C-1109

The stapler home sensor (PS40) does not turn ON within a specified period of time after the stapler motor (M31) starts operations.

 

C-1113

The stacker rear stopper home sensor (PS27) does not turn ON within a specified period of time after the home position search operation of the stacker movement motor (M19) starts.

 

C-1114

The rewind paddle release home sensor (PS38) does not turn ON even after a specified period of time after the rewind paddle release home motor (M28) starts the home position search operation.

FS: FS-510 abnormality

C-1115

The 1st folding knife home sensor (PS110) does not turn ON within a specified period of time after thelst

 

 

folding knife motor (M107) turns ON.

PI: PI

abnormality

C-1124

The tray upper limit sensor /Lw (PS209) or the tray lower limit sensor /Lw (PS210) does not turn ON within a specified period of time after the tray lift motor /Lw (M202) turns ON.

 

C-1125

The tray upper limit sensor /Up (PS205) or the tray lower limit sensor /Up (PS204) does not turn ON within a specified period of time after the tray up down motor /Up (M201) turns ON.

PK: PK abnormality

C-1127

The punch shift home sensor (PS303) does not turn ON within a specified period of time after the punch shift motor (M302) turns ON.

ZU: ZU-608 abnormality

C-1130

1st folding stopper home sensor (PS603) does not turned ON within a specified period of time after the 1st folding stopper motor (M602) starts the home position search operation.

 

C-1131

2nd folding stopper home sensor (PS604) does not turned ON within a specified period of time after the 2nd folding stopper motor (M603) starts the home position search operation.

PK: PK abnormality

C-1132

The punch home sensor (PS301) does not turn ON within a specified period of time after the punch motor (M301) turns ON.

ZU: ZU-608 abnormality

C-1133

The punch shift home sensor (PS605) does not turn ON even after a specified period of time after the punch shift motor (M605) starts the home position search operation.

 

C-1134

An error detection signal of FM601 is detected continuously for a specified period of time while the main motor cooling fan (FM601) is ON.

 

C-1135

After the punch motor (M604) turns ON, M604 does not turn ON within a specified period of time.

ZU: ZU-608 abnormality

C-11З6

After the punch switchover motor (M608) turns ON, punch switchover switch (MS601) does not turn ON from OFF, or not turn OFF from ON within a specified period of time.

FS: FS-532 abnormality

C-1137

The conveyance gate home sensor (PS31) does not turn ON within a specified period of time after the conveyance gate motor (M22) turns ON.

 

C-1141

After the stack assist motor (M8) turns ON, the stack assist home sensor (PS11) does not turn ON within a specified period of time.

 

C-1144

The paper exit alignment plate home sensor (PS20) does not turn ON within a specified period of time after the paper exit alignment plate motor (M12) turns ON.

 

C-1147

The paper exit alignment plate up down home sensor (PS21) does not turn ON within a specified period of time after the paper exit alignment plate up down motor (M13) turns ON.

 

C-1153

The main tray home sensor (PS23) does not turn ON within a specified period of time after the tray shift roller motor (M15) turns ON.

 

C-1154

After the gripper exit sensor /Lw (M16) turns ON, the gripper home sensor /Up (PS24) does not turn ON within a specified period of time.

 

C-1155

After the gripper exit sensor /Lw (M17) turns ON, the gripper home sensor /Lw (PS25) does not turn ON within a specified period of time.

 

C-1156

After the stacker rear stopper motor (M20) turns ON, the stacker rear stopper home sensor (PS29) does not turn ON within a specified period of time.

 

C-1157

After the stacker paper press motor (M21) turns ON, the stacker paper press home sensor (PS30) does not turn ON within a specified period of time.

 

C-1158

After the roller pressure motor (M27) turns ON, the roller pressure motor home sensor (PS34) does not turn ON within a specified period of time.

 

C-1159

The bypass gate home sensor (PS36) does not turn ON within a specified period of time after the bypass gate motor (M25) turns ON.

 

C-1170

The exit paper press home sensor (PS37) does not turn ON within a specified period of time after the exit paper press motor (M26) turns ON.

 

C-1171

The small size paper alignment home sensor (PS26) does not turn ON within a specified period of time after the small size paper alignment motor (M18) turns ON.

 

C-1172

An error detection signal of FM1 is detected continuously for a specified period of time while the large size paper alignment fan (FM1) is ON.

FS: FS-510 abnormality

C-1173

The stapler shift home sensor (PS105) does not turn ON within a specified period of time after the stapler movement motor (M103) turns ON.

 

C-1174

The operation does not complete within a specified period of time after the SD saddle stapler motor (M102) starts operations,

 

C-1175

After the stopper motor (M105) turns ON, the stopper home sensor (PS107) does not turn ON within a specified period of time.

 

C-1176

After the center paddle motor (M106) turns ON, the center paddle home sensor (PS108) does not turn ON within a specified period of time.

 

C-1177

The 2nd folding knife home sensor (PS111) does not turn ON within a specified period of time after the 2nd folding knife motor (M110) turns ON.

FS: FS-532 abnormality

C-1179

RUKA communication error

FS: FS-510 abnormality

C-1180

The alignment home sensor (PS106) does not

 

 

turn ON within a specified period of time after the saddle stitching alignment motor (M104) turns ON.

 

C-1181

After the lower paddle motor (M109) turns ON, the lower paddle home sensor (PS114) does not turn ON within a specified period of time.

LS (1st tandem): LS abnormality

C-1201

The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time.

 

C-1202

The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time.

 

C-1203

The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. Or, PS12 does not turn ON within a specified period of time.

 

C-1204

The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON.

 

C-1205

The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation.

 

C-1206

The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation.

LS (2nd tandem): LS abnormality

C-1211

The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time.

 

C-1212

The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time.

 

C-1213

The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. Or, PS12 does not turn ON within a specified period of time.

 

C-1214

The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON.

 

C-1215

The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation.

 

C-1216

The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation.

FD: FD abnormality

C-1221

The 1st folding cam home sensor (PS55) does not turn ON within a specified period of time after the 1st folding release motor (M14) turns ON.

 

C-1222

The 2nd folding cam home sensor (PS56) does not turn ON within a specified period of time after the 2nd folding release motor (M15) turns ON.

 

C-1223

The 3rd folding cam home sensor (PS57) does not turn ON within a specified period of time after the 3rd folding release motor (M16) turns ON.

 

C-1224

The 2 holes punch home sensor (PS8) does not turn OFF within a specified period of time after the 2- holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 2 holes punch home sensor (PS8) does not turn OFF.

 

C-1225

The 3 holes/4 holes punch home sensor (PS9) does not turn OFF within a specified period of time after the 3 holes/4 holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 3 holes/4 holes punch home sensor (PS9) does not turn OFF.

 

C-1226

The alignment plate home sensor (PS10) does not turn ON within a specified period of time after the alignment plate home position return operation starts. Or, after the alignment motor (M12) turns ON, the alignment plate home sensor (PS10) does not turn OFF.

 

C-1227

The punch registration home sensor (PS11) does not turn ON within a specified period of time after the punch registration claw home position return operation starts. Or, after the punch registration motor (M13) turns ON, the punch registration home sensor (PS11) does not turn OFF.

 

C-1228

The main tray upper limit sensor (PS20) does not turn ON within a specified period of time after the main tray home position search starts. Or, after the tray up down motor (M11) turns ON, the main tray upper limit sensor (PS20) does not turn OFF.

 

C-1229

The main tray lower limit sensor (PS22) does not turn ON within a specified period of time after the tray up down motor (M11) is in the down operation.

 

C-1230

After the FD paper lift motor /Up (M8) is in the down operation, the PI lift plate home sensor /Up (PS34) does not turn ON within a specified period of time. Or, after the paper lift motor /Up (M8) is in the up operation, the PI tray upper limit sensor /Up (PS32) does not turn ON.

 

C-1231

After the FD paper lift motor /Lw (M9) is in the down operation, the PI lift plate home sensor /Lw (PS40) does not turn ON within a specified period of time. Or, after the paper lift motor /Lw (M9) is in the up operation, the PI upper limit sensor /Lw (PS38) does not turn ON.

 

C-1232

An error detection signal is detected continuously for a specified period of time while the entrance conveyance motor (M1) is ON.

 

C-1233

An error detection signal of M3 is detected continuously for a specified period of time while the intermediate conveyance motor (M3) is ON.

 

C-1234

An error detection signal of M7 is detected continuously for a specified period of time while the PI conveyance motor (M7) is ON.

 

C-1235

An error detection signal of M17 is detected continuously for a specified period of time while the main tray exit motor (M17) is ON.

SD: SD-506 abnormality

C-1241

The scraps press home sensor (PS48) does not turn ON within a specified period of time after the bundle exit motor (M5) starts the home position search operation.

 

C-1242

The folding main scan alignment home sensor / Fr1 (PS18) does not turn ON within a specified period of time after the folding main scan alignment motor /Fr (M7) starts the home position search operation. Or, even after a specified period of time after M7 starts the operation, it does not stop.

 

C-1243

The folding exit home sensor (PS24) does not turn ON within a specified period of time after the folding sub scan alignment exit motor (M8) starts the home position search operation. Or, even after a specified period of time after M8 starts to decelerate, it does not stop.

 

C-1244

The saddle stitching alignment home sensor /Rt (PS28) does not turn ON within a specified period of time after the saddle stitching alignment motor / Rt (M9) starts the home position search operation. Or, even after a specified period of time after M9 starts the operation, it does not stop.

 

C-1245

The bundle arm home sensor (PS32) does not turn ON within a specified period of time after the bundle arm motor (M10) starts the home position search operation. Or, even after a specified period of time after M10 starts the operation, it does not stop.

 

C-1246

The bundle clip upper limit sensor (PS33) does not turn ON within a specified period of time after the bundle clip motor (M11) starts the home position search operation. Or, even after a specified period of time after M11 starts the operation, it does not stop.

 

C-1247

The bundle registration home sensor (PS34) does not turn ON within a specified period of time after the bundle registration motor (M12) starts the home position search operation. Or, even after a specified period of time after M12 starts the operation, it does not stop.

 

C-1248

The overlap home sensor (PS17) does not turn ON within a specified period of time after the overlap motor (M13) starts the home position search operation. Or, even after a specified period of time after M13 starts the operation, it does not stop.

 

C-1249

The folding main scan alignment home sensor /Rr (PS19) does not turn ON within a specified period of time after the folding main scan alignment motor /Rr (M14) starts the home position search operation. Or, even after a specified period of time after M14 starts the operation, it does not stop.

 

C-1250

The stapler movement home sensor (PS25) does not turn ON within a specified period of time after the home position search operation of the stapler movement motor (M15) starts. Or, even after a specified period of time after M15 starts the operation, it does not stop.

 

C-1251

The saddle stitching alignment home sensor /Lt (PS29) does not turn ON within a specified period of time after the saddle stitching alignment motor / Lt (M16) starts the home position search operation. Or, even after a specified period of time after M16 starts the operation, it does not stop.

 

C-1252

The bundle press movement home sensor (PS36) does not turn ON within a specified period of time after the bundle press movement motor (M17) starts the home position search operation. Or, even after a specified period of time after M17 starts the operation, it does not stop.

 

С-125З

The 1st folding blade home sensor (PS21) does not turn ON within a specified period of time after the 1st folding blade motor (M18) starts the home position search operation. Or 1st folding blade home sensor /1 (PS20) does not turned ON within a specified period of time after M18 starts the operation.

 

C-1254

The 2nd folding blade home sensor /2 (PS23) does not turn ON within a specified period of time after the 2nd folding blade motor (M19) starts the home position search operation. Or the 2nd folding blade home sensor /1 (PS22) does not turned ON within a specified period of time after M19 starts the operation.

 

C-1255

The clincher up down home sensor (PS26) does not turn ON even after a specified period of time after the clincher up down motor (M20) starts the home position search. Or, even after a specified period of time after M20 starts the operation, it does not stop.

 

C-1256

The saddle stitching press home sensor (PS27) does not turn ON within a specified period of time after the saddle stitching press motor (M21) starts the home position search operation. Or, even after a specified period of time after M21 starts the operation, it does not stop.

 

C-1257

The bundle arm rotation home sensor (PS31) does not turn ON within a specified period of time after the bundle arm rotation motor (M22) starts the home position search operation. Or, even after a specified period of time after M22 starts the operation, it does not stop.

 

C-1258

The bundle press home sensor (PS37) does not turn ON within a specified period of time after the bundle press motor (M23) starts the home position search operation. Or, even after a specified period of time after M23 starts the operation, it does not stop.

 

C-1259

The bundle press home sensor (PS35) does not turn ON within a specified period of time after the bundle press stage up down motor (M24) starts the home position search operation. Or PS35 or the bundle press stage up down upper limit sensor (PS45) does not turned ON after a specified period of time M24 starts the operation.

 

C-1260

The guide shaft home sensor (PS46) does not turn ON even after a specified period of time after the guide shaft motor (M25) starts the home position search operation. Or, even after a specified period of time after M25 starts the operation, it does not stop.

 

C-1261

The stapler home sensor / Rt (HS1) or the clincher start sensor /Rt (HS2) does not turn ON even after a specified period of time after the stapler motor /Rt (M29) starts the operation.

 

C-1262

The stapler home sensor / Lt (HS3) or the clincher start sensor /Lt (HS4) does not turn ON even after a specified period of time after the stapler motor /Lt (M30) starts the operation.

 

C-1263

It does not stop even after a specified period of time after the trimmer blade motor (M31) starts the operation.

 

C-1264

It does not stop even after a specified period of time after the trimmer press motor (M32) starts the operation.

 

C-1265

It does not stop even after a specified period of time after the bundle arm assist motor (M26) starts the operation.

 

C-1266

Rotation abnormality is detected for a specified period of time in succession while the entrance conveyance motor (M1) is driving.

 

C-1267

Rotation abnormality is detected for a specified period of time in succession while the horizontal conveyance motor (M2) is driving.

 

C-1268

Rotation abnormality is detected for a specified period of time in succession while the folding entrance motor (M3) is driving.

 

C-1269

Rotation abnormality is detected for a specified period of time in succession while the folding transfer motor (M4) is driving.

 

C-1270

Rotation abnormality is detected for a specified period of time in succession while the bundle exit motor (M5) is driving.

 

C-1271

Rotation abnormality is detected for a specified period of time in succession while the folding sub scan alignment exit motor (M8) is driving.

 

C-1272

Rotation abnormality is detected for a specified period of time in succession while the trimmer paddle motor (M33) is driving.

 

C-1273

The trimmer completion sensor (PS62) does not turn ON even after a specified period of time after the trimmer blade motor (M31) is in the up operation.

 

C-1275

The wire slack sensor (PS66) detected the slack of the trimmer edge drive wire.

RU: RU-510 abnormality

C-1281

FD alignment motor (M3) drive abnormality.

The CD alignment home sensor (PS3) does not turn ON even after a specified period of time after M3 starts the home position search operation. Or, even after a specified period of time after M3 starts the operation, it does not stop.

 

C-1282

CD alignment motor (M4): drive abnormality.

The CD alignment home sensor (PS4) does not turn ON even after a specified period of time after M4 starts the home position search operation. Or, even after a specified period of time after M4 starts the operation, it does not stop.

RU: RU-509 abnormality

C-1290

Rotation abnormality is detected for a specified period of time in succession while the de­curler conveyance motor (M3) is driving.

 

C-1291

The home position search operation of the de-curler pressure motor /Lw (M5) does not complete within a specified period of time.

 

C-1292

The home position search operation of the de-curler pressure motor /Up (M6) does not complete within a specified period of time.

 

C-1293

Rotation abnormality is detected for a specified period of time in succession while the humidification section conveyance motor (M8) is driving.

 

C-1294

The home position search operation of the humidification section roller pressure motor /Rt (M9) does not complete within a specified period of time.

 

C-1295

The home position search operation of the humidification section roller pressure motor /Lt (M10) does not complete within a specified period of time.

 

C-1299

The water tank full sensor (PS13) detects ON continuously for more than a specified period of time.

LS (1st tandem): LS abnormality

C-1301

An error detection signal is detected continuously for a

 

 

specified period of time while the paper cooling fan motor /Fr (FM1) is ON.

 

C-1302

An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /1 (FM2) is ON.

 

C-1303

An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor/Mi (FM3) is ON.

 

C-1304

An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON.

 

C-1305

An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan motor /Rr (FM5) is ON.

LS (2nd tandem): LS abnormality

C-1306

An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Fr (FM1) is ON.

 

C-1307

An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor/1 (FM2) is ON.

 

C-1308

An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Mi (FM3) is ON.

 

C-1309

An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON.

 

C-1310

An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan motor /Rr (FM5) is ON.

SD: SD-506 abnormality

C-1311

A rotation error detection signal is detected continuously for specified period of time while the scraps removal fan motor (FM1) is started or driving.

LS (3rd tandem): LS abnormality

C-1316

An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Fr (FM1) is ON.

 

C-1317

An error detection signal is detected continuously for a specified period of time while the paper cooling fan /1 (FM2) is ON.

 

C-1318

An error detection signal is detected continuously for a specified period of time while the paper cooling fan /Mi (FM3) is ON.

 

C-1319

An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON.

 

C-1320

An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan /Rr (FM5) is ON.

PB: PB abnormality

C-1330

A rotation error detection signal is detected continuously for specified time period while the cover paper tray fan /1 (FM71) is started or driving.

 

C-1331

A rotation error detection signal is detected continuously for specified time period while the cover paper tray fan /2 (FM72) is started or driving.

 

C-1332

A rotation error detection signal is detected continuously for a specified time period while the exhaust fan /1 (FM80) is started or driving.

 

C-1333

A rotation error detection signal is detected continuously for a specified time period while the exhaust fan /2 (FM81) is started or driving.

 

C-1334

A rotation error detection signal is detected continuously for specified period of time while the pellet supply cooling fan (FM4) is started or driving.

RU: RU-510 abnormality

C-1341

Stack assist fan /Fr (FM1) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM1 operation.

 

C-1342

Stack assist fan /Rr (FM2) rotation abnormality. Rotation abnormality detected continuously for the specified time during FM2 operation.

RU: RU-509 abnormality

C-1351

Error detection signals of FM/1, FM/2 and FM/3 are detected continuously for a specified period of time while the entrance paper fans /1 (FM1), /2 (FM2) and /3 (FM3) are ON.

 

C-1352

Error detection signals of FM4 and FM5 are detected continuously for a specified period of time while the ventilation assist fans /1 (FM4) and /2 (FM5) are ON.

 

C-1353

Error detection signals of FM15, FM16 and FM17 are detected continuously for a specified period of time while the entrance paper fans /4 (FM15), /5 (FM16) and /6 (FM17) are ON.

 

C-1354

Error detection signals of FM18, FM19 and FM20 are detected continuously for a specified period of time while the entrance paper fans /7 (FM18), /8 (FM19) and /9 (FM20) are ON.

 

C-1355

Error detection signals of FM21 is detected continuously for a specified period of time while the ventilation assist fan /3 (FM21) is ON.

 

C-1356

An error detection signal of FM6 is detected continuously for a specified period of time while the humidification section paper fan /1 (FM6) is ON.

 

C-1357

An error detection signal of FM7 is detected continuously for a specified period of time while the humidification section paper fan /2 (FM7) is ON.

 

C-1358

An error detection signal of FM8 is detected continuously for a specified period of time while the humidification section paper fan /3 (FM8) is ON.

 

C-1359

An error detection signal of FM9 is detected continuously for a specified period of time while the humidification section paper fan /4 (FM9) is ON.

 

C-1360

An error detection signal of FM10 is detected continuously for a specified period of time while the humidification section paper fan /5 (FM10) is ON.

 

C-1361

An error detection signal of FM11 is detected continuously for a specified period of time while the humidification section paper fan /6 (FM11) is ON.

 

C-1364

An error detection signal of FM14 is detected continuously for a specified period of time while the humidification section paper fan (FM14) is ON.

FS: FS-532 abnormality

C-1402

Non-volatile memory abnormality.

FD: FD abnormality

C-1403

Non-volatile memory abnormality.

SD: SD-506 abnormality

C-1404

Non-volatile memory abnormality.

PB: PB abnormality

C-1406

Non-volatile memory abnormality in the PB control board (PBCB)

RU: RU-509 abnormality

C-1407

Non-volatile memory abnormality.

RU: RU-510 abnormality

C-1408

Non-volatile memory abnormality.

SD: SD-506 abnormality

C-1411

5V power abnormality in the SD drive board (SDDB)

FS: FS-532 abnormality

C-1412

24V activation failure

FD: FD abnormality

C-1432

Communication error in FD

SD: SD-506 abnormality

C-1433

Communication error in SD

PB: PB abnormality

C-1435

Message queue full or the control abnormality of Sub CPU1 in the PB control board (PBCB)

 

C-1436

Message queue full or the control abnormality of Sub CPU2 in the PB control board (PBCB)

 

C-1437

Message queue of the communication among tasks in the PB is full.

RU: RU-509 abnormality

C-1438

Communication error in RU

RU: RU-510 abnormality

C-1439

Communication error in RU

FS: FS-532/

SD-510

abnormality

C-1442

Communication error between FS-532 and SD-510.

FD: FD abnormality

C-1451

When the FD is unready, a signal to start operations is received from the main body.

SD: SD-506 abnormality

C-1452

When the SD is unready, a signal to start operations is received from the main body.

PB: PB abnormality

C-1454

PB operation prohibition abnormality.

PB received operation start signal from the main body when the PB is unready.

RU: RU-509 abnormality

C-1455

When RU is unready, a signal to start operations is received from the main body.

RU: RU-510 abnormality

C-1456

When RU is unready, a signal to start operations is received from the main body.

 

C-1499

Logical contradiction error

PB: PB abnormality

C-1501

The entrance conveyance has not been completed within a specified period of time after the entrance conveyance motor (M1) turns ON.

 

C-1502

A rotation error detection signal is detected for a specified period of time in succession while the intermediate conveyance motor (M2) is driving.

 

C-1504

The SC entrance conveyance has not been completed within a specified period of time after the SC entrance conveyance motor (M11) turns ON.

 

C-1505

The switchback conveyance has not been completed within a specified period of time after the SC switchback conveyance motor (M12) turns ON.

 

C-1506

The switchback roller release operation has not been completed within a specified period of time after the SC switchback release motor (M13) turns ON.

 

C-1507

The SC alignment has not been completed within a specified period of time after SC alignment motor (M15) turns ON.

 

C-1508

The SC paper bundle conveyance has not been completed within a specified period of time after the SC bundle conveyance motor (M17) turns ON.

 

C-1509

The SC roller release operation has not been completed within a specified period of time after the SC roller release motor (M18) turns ON.

 

C-1510

The SC entrance movement operation has not been completed within a specified period of time after the clamp entrance movement motor (M19) turns ON.

 

C-1511

The clamp entrance roller release operation has not been completed within a specified period of time after the clamp entrance roller release motor (M20) turns ON.

 

C-1512

The clamp alignment has not been completed within a specified period of time after clamp alignment motor (M21) turns ON.

 

C-1513

The clamp section open/ close operation has not been completed within a specified period of time after the clamp motor (M22) turns ON.

 

C-1514

The clamp rotation operation has not been completed within a specified period of time after the clamp rotation motor (M23) turns ON.

 

C-1515

The glue tank movement operation has not been completed within a specified period of time after the glue tank movement motor (M31) turns ON.

 

C-1516

A rotation error detection signal is detected for a specified period of time in succession while the glue apply roller motor (M32) is driving.

 

C-1517

The count of a specified number of pellets, which is counted by the pellet supply passage sensor (PS37), has not been reached after the pellet supply pipe motor (M33) turns ON.

 

C-1518

The operation of the pellet supply arm has not been completed within a specified period of time after the pellet supply arm motor (M34) turns ON.

 

C-1519

The alignment in the cover paper table up/down section has not been completed within a specified period of time after the cover paper alignment motor (M41) turns ON.

 

C-1520

The booklet exit has not been completed within a specified period of time after the booklet exit motor (M42) turns ON.

 

C-1521

The driven arm /Rt swing operation start has not been completed within a specified period of time after the cover paper conveyance arm motor /Rt (M43) turns ON

 

C-1522

The driven arm /Lt swing operation start has not been completed within a specified period of time after the cover paper conveyance arm motor /Lt (M44) turns ON

 

C-1523

The cover paper conveyance start has not been completed within a specified period of time after cover paper conveyance motor (M45) turns ON.

 

C-1524

The cover paper table up or down movement has not been completed within a specified period of time after the cover paper table up down motor /Fr (M46) turns ON.

 

C-1525

The cover paper table up or down movement has not been completed within a specified period of time after the cover paper table up down motor /Rr (M47) turns ON.

 

C-1526

The movement of the cover paper folding plate / Rt has not been completed within a specified period of time after the cover paper folding motor /Rt (M48) turns ON.

 

C-1527

The movement of the cover paper folding plate / Lt has not been completed within a specified period of time after the cover paper folding motor /Lt (M49) turns ON.

 

C-1528

The trimming of the cover paper has not been completed within a specified period of time after the cutter motor (M50) turns ON.

 

C-1530

The booklet movement of the booklet conveyance section has not been completed within a specified period of time after the booklet conveyance belt motor (M61) turns ON.

 

C-1531

The size changing operation of the carriage section has not been completed within a specified period of time after the booklet conveyance belt movement motor (M62) turns ON.

 

C-1532

The up/down movement operation of the carriage section has not been completed within a specified period of time after the booklet conveyance belt up down motor (M63) turns ON.

 

C-1534

The booklet rear edge pressing process has not been completed within a specified period of time after the booklet stopper motor (M65) turns ON.

 

C-1537

The tray moving up process has not been completed within a specified period of time after the cover paper tray lift motor (M73) turns ON.

 

C-1538

The cover paper feed has not been completed within a specified period of time after the cover paper feed motor (M74) turns ON.

 

C-1540

After the warm-up is started, temperature detected by the glue tank temperature sensor /Md (TH3) has not risen to a prescribed level within a specified time period.

 

C-1541

After the warm-up is started, temperature detected by the glue tank temperature sensor /Lw (TH4) has not risen to a prescribed level within a specified time period.

 

C-1542

After the warm-up is started, temperature detected by the glue apply roller temperature sensor (TH1) has not risen to a prescribed level within a specified time period.

 

C-1543

After the pellet supply, temperature detected by the glue tank temperature sensor /Up (TH2) has not risen to a prescribed level within a specified period of time.

 

C-1544

During standby, after the glue tank heater (H1) is turned ON, temperature detected by the glue tank temperature sensor /Md (TH3) has not risen to a prescribed level within a specified time period.

 

C-1545

When the prescribed temperature is obtained and after the glue tank heater (H1) is turned ON, temperature detected by the glue tank temperature sensor /Lw (TH4) has not risen to a prescribed level within a specified time period.

 

C-1546

When the prescribed temperature is obtained and after the glue tank heater (H1) is turned ON, temperature detected by the glue apply roller temperature sensor (TH1) has not risen to a prescribed level within a specified time period.

 

C-1547

The glue apply roller temperature sensor (TH1) detects an abnormal high temperature.

 

C-1548

The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature.

 

C-1549

The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature.

 

C-1550

The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature.

 

C-1551

The glue apply roller temperature sensor (TH1) detects an abnormal high temperature (hardware) TH1 detects an abnormal high temperature of the glue apply roller.

 

C-1552

The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature (hardware). TH2 detects an abnormal high temperature of the glue tank.

 

C-1553

The glue tank temperature sensor /Md (TH3) detects an abnormal high temperature (hardware). TH3 detects an abnormal high temperature of the glue tank.

 

C-1554

The glue tank temperature sensor /Lw (TH4) detects an abnormal high temperature (hardware). TH4 detects an abnormal high temperature of the glue tank.

 

C-1555

After warming-up is completed, the glue apply roller temperature sensor (TH1) detects an abnormal low temperature.

 

C-1556

When glue supply control temperature is reached, the glue tank temperature sensor /Up (TH2) detects an abnormal low temperature.

 

C-1557

After warming-up is completed, the glue tank temperature sensor /Md (TH3) detects an abnormal low temperature.

 

C-1558

After warming-up is completed, the glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature.

 

C-1559

The glue apply roller temperature sensor (TH1) detects an abnormal low temperature (hardware). After warming-up is completed, TH1 detects the glue apply roller error signal of abnormal low temperature.

 

C-1560

The glue tank temperature sensor /Up (TH2) detects an abnormal low temperature (hardware). After glue supply control temperature is reached, TH2 detects the glue tank error signal of abnormal low temperature.

 

C-1561

The glue tank temperature sensor /Md (TH3) detects an abnormal low temperature (hardware). After warming-up is completed, TH3 detects the glue tank error signal of abnormal low temperature.

 

C-1562

The glue tank temperature sensor /Lw (TH4) detects an abnormal low temperature (hardware). After warming-up is completed, TH4 detects the glue tank error signal of abnormal low temperature.

 

C-1565

Relay conveyance motor drive abnormality

 

C-1566

Relay conveyance exit motor drive abnormality A rotation error detection signal is detected for a specified period of time in succession while the relay conveyance exit motor (M91) is driving.

 

C-1567

Pellet supply pipe motor drive abnormality The pellet supply pipe has not completed the operations within a specified period of time after the pellet supply pipe motor (M33) turns ON.

LS (3rd tandem): LS abnormality

C-1651

The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after the stacker tray up down motor (M1) turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time.

 

C-1652

The shift unit home sensor (PS11) does not turn ON within a specified period of time after the shift unit motor (M5) turns ON. Or, PS11 does not turn ON within a specified period of time.

 

C-1653

The alignment plate home sensor (PS12) does not turn ON within a specified period of time after the alignment motor (M7) turns ON. Or, PS12 does not turn ON within a specified period of time.

 

C-1654

The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after the grip conveyance motor (M4) turns ON.

 

C-1655

The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation.

 

C-1656

The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation.

Main body: Wire

cleaning

abnormality

C-2101

Charger cleaning motor (M23) operation time abnormality.

Main body : Wire

cleaning

abnormality

C-2102

Charger cleaning motor (M23) power abnormality.

Main body: Wire

cleaning

abnormality

C-2103

Charger cleaning motor (M23) drive abnormality.

Main body: Motor

abnormality

C-2201

Toner bottle motor (M6) speed abnormality.

An error detection signal is detected twice in succession within a specified period of time after M6 was turned ON.

 

C-2202

Developing motor (M3) speed abnormality.

Since an error detection signal is detected a second after M3 turns ON, turn OFF M3 for 0.5 seconds. Then, an error detection signal is detected again a second after it is turned ON again.

 

C-2203

The locking of the blade motor (M22) is detected. The error detection signal (over current) of M22 is detected.

 

C-2204

Drum motor (M2) drive abnormality + 24V power abnormality.

The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal (24V cut off) is detected.

 

C-2205

Drum motor (M2) power abnormality.

The drum READY1 signal (READY condition) cannot be detected within a specified period of time after the drum motor (M2) turns ON. Or, the drum READY1 signal (READY release condition) cannot be detected within a specified period of time after M2 turns OFF. At this time, an error detection signal (blowout of ICP) of the blade motor (M22) is detected.

 

C-2206

Drum motor (M2) drive abnormality.

 

C-2207

Drum motor (M22) drive abnormality + 24V power abnormality.

The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (24V cut off) is detected.

 

C-2208

Blade motor (M22) power abnormality.

The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (blowout of ICP) of the blade motor (M22) is detected.

 

C-2209

It is checked that the movement of the blade motor (M22) is not completed.

The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal is not detected.

 

C-2210

The drum motor (M2) does not start.

The drum READY2 signal (READY signal) is not detected within a specified period of time after M2 turns ON.

 

C-2211

Intermediate hopper motor (M11) power abnormality. An error detection signal (blowout of ICP) is detected when M11 turns ON.

 

C-2212

Air separation motor (M10) power abnormality.

An error detection signal (blowout of ICP) is detected when M10 turns ON.

 

C-2213

Air separation motor (M10) rotation abnormality.

Since an error is detected when M10 turns ON, turn it OFF. An error is still detected when turn it ON again.

 

C-2214

The toner conveyance abnormality is detected. When executing the toner supply operation for 8 minutes, the intermediate hopper toner remaining sensor (PS39) does not turn ON and the hopper toner remaining sensor /2 (PS33) detects ON in succession for 15 seconds.

 

C-2215

Hopper toner remaining sensor /2 (PS33) abnormality.

When the toner is supplied for 8minutes, it is found that the toner remaining sensor /1 (PS32) does not turn ON and the hopper toner remaining sensor /2 (PS33) turns OFF for the last 15 seconds in succession.

 

C-2217

Leakage at the mixing section is detected.

When the toner pump motor (M28) is operating, the cup section toner remaining sensor (PS34) detects the toner being provided in succession for seconds.

 

C-2220

Toner pump motor (M28) rotation abnormality + 24V power abnormality.

While M28 is rotating, an error detection signal (abnormal rotation/24V cut off) is detected for more than 1second.

 

C-2221

Toner pump motor (M28) power abnormality.

While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an abnormality signal (blowout of ICP) is detected, but no abnormality signal (24V cut off) is detected.

 

C-2222

Toner pump motor (M28) rotation abnormality. While M28 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error detection signal (blowout of ICP/24V cut off) is not detected.

 

C-2224

Air pump motor (M29) rotation abnormality + 24V power abnormality.

While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error signal (24V cut off) is detected.

 

C-2225

Air pump motor (M29) power abnormality.

While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an abnormality signal (blowout of ICP) is detected, but no abnormality signal (24V cut off) is detected.

 

C-2226

Air pump motor (M29) rotation abnormality.

While M29 is rotating, an error detection signal (abnormal rotation) is detected for more than 1second. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected.

 

C-2227

Developing screw motor (M21) rotation abnormality. The M21EM error detection signal is detected twice in succession within a specified period of time after M21 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-2228

The transfer belt motor (M30) rotation abnormality. The M30EM error detection signal is detected twice in succession within a specified period of time after M30 was turned ON. However, an error detection signal (blowout of ICP) is not detected.

 

C-2230

Waste toner box swing motor (M19) drive abnormality.

The waste toner box swing sensor (PS15) ON or OFF is not detected twice in succession within a specified period of time after M19 turns ON.

 

C-2231

De-curler motor (M32) rotation abnormality.

The M32EM error detection signal is detected twice in succession within a specified period of time after M32 was turned ON, and the main door detection is Close.

 

C-2233

Waste toner box swing motor (M19) rotation abnormality.

The M19EM error detection signal is not detected twice in succession within a specified period of time after M19 was turned ON.

 

C-2234

Transfer belt pressure release motor (M26) operation time abnormality 1.

When M26 moves from the HP position to the pressure position, the transfer pressure position sensor /1 or /2 (PS55 or PS56) does not turn ON within a specified period of time. At this time, the main door detection is Close.

 

C-2235

Transfer belt pressure release motor (M26) operation time abnormality 2.

 

C-2236

Abnormality of the transfer belt pressure release motor (M26) IC in the ADU drive board (ADUDB).

An error detection signal of M26 is detected after the print is started.

 

C-2237

Waste toner motor (M9) rotation abnormality.

The M9EM error detection signal is detected twice in succession within a specified period of time after M9 was turned ON.

 

C-2238

Blade motor (M22) abnormality.

Waste blade motor does not move to the weak pressure position within a specified period of time after M22 turns ON.

 

C-2241

Abnormality of the intermediate hopper motor (M11) drive in the printer control board (PRCB).

 

C-2242

Drum cleaner motor (M35) abnormality The M35 EM error detection signal is detected twice in succession within a specified period of time after M35 was turned ON.

Main body: Fan abnormality

C-2304

Developing suction fan (FM22) rotation abnormality + 24V power abnormality.

The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-2306

Developing suction fan (FM22) rotation abnormality.

The FM5 EM error detection signal is detected twice in succession within a specified period of time after FM22 was turned ON. However, error detection signal (24V cut off) is not detected.

 

C-2307

Developing cooling fan /Up (FM31) rotation abnormality + 24V power abnormality.

The FM31EM error detection signal is detected twice in succession within a specified period of time after FM31 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-2309

Developing cooling fan (FM31) rotation abnormality.

The FMx EM error detection signal is detected twice in succession within a specified period of time after FMx was turned ON. However, error detection signal (24V cut off) is not detected.

 

C-2311

Developing cooling fan (FM11) rotation abnormality + 24V power abnormality.

The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-2313

Pump cooling fan (FM11) rotation abnormality.

The FM11 EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, error detection signal (24V cut off) is not detected.

 

C-2317

Charger exhaust fan (FM44) rotation abnormality + 24V power abnormality.

The FM44 EM error detection signal is detected twice in succession within a specified period of time after FM44 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-2318

Charger exhaust fan (FM44) rotation abnormality.

The FM44 EM error detection signal is detected twice in succession within a specified period of time after FM44 was turned ON. However, error detection signal (24V cut off) is not detected.

Main

body:Power

abnormality

C-2401

The fall-off of the erase lamp (EL) CN is detected. When turning ON the power, an error detection signal (fall-off) is detected a specified period of time after the fall-off detection control signal of the EL CN turns ON.

Main body: Drum

C-2402

Drum temperature sensor wiring harness breakage. When the change in temperature of the drum temperature sensor (TH5) is less than -2°C a specified period of time after the main power switch (SW1) turns ON to start the control of the dehumidification heater /1 (HTR1) and the drum temperature is below 10°C after 1minute.

 

C-2403

Drum temperature sensor wiring harness breakage. When the main power switch (SW1) turns ON with the fusing temperature below 50°C, the detected temperature of the drum temperature sensor (TH5) is more than 52°C, and when the detected temperature is above 52°C after a specified period of time.

 

C-2411

TCR sensor (TCRS) output abnormality 1.

The TCRS output is detected more than 3.0V (153step) in printing.

 

C-2412

TCR sensor (TCRS) output abnormality 2.

The TCRS output is detected more than 0.5V (25step) in printing.

 

C-2413

TCR sensor (TCRS) output abnormality 3.

Main body: High voltage power source abnormality

C-2701

A charge leak is detected. After a charge EM signal abnormality is detected while in the charge ON, up to 5 charge ON/OFF operations occur in succession while in 10 prints.

 

C-2702

A transfer leak is detected. After a transfer EM signal abnormality is detected while in the charge ON, up to 5 transfer ON/OFF operations occur in succession while in 10 prints.

 

C-2704

24V high voltage power abnormality.

An error detection signal (blowout of ICP) of 24V high voltage power is detected. At this time, the main door detection and the PFU door detection are Close.

 

C-2705

PCC leak is detected.

After a PCC EM signal abnormality is detected while in the PCC ON, up to 5 transfer ON/OFF operations occur in succession while in 10 prints.

Main body:

Process

abnormality

C-2801

IDC sensor (TCB) dirt correction abnormality. While in the maximum density correction (Dmax), the IDC sensor (TCB) dirt correction abnormality is detected 10 times in succession.

 

C-2802

The maximum density correction (Dmax) is not completed.

While in Dmax, the number of rotations of the developing sleeve gets to the maximum.

 

C-2803

The IDC sensor (TCB) output abnormality.

While in the maximum density correction (Dmax), a patch for control is not output. (No output is made from the gamma sensor.)

 

C-2804

The dirt correction of the IDC sensor is not completed.

 

C-2807

Drum potential sensor (DPS) output abnormality 1.

The DPS detects the value less than the potential specified value of the unexposed part 5 times in succession.

 

C-2808

Dot diameter correction abnormality.

While in the dot diameter correction, the correction is terminated with an abnormal value.

 

C-2809

Drum potential sensor (DPS) output abnormality 2.

While in the 0V check of the DPS, more than 100V of the drum surface potential is detected more than 5 times. When this condition is detected 5 times in succession, the error code is displayed.

 

C-2810

Drum potential sensor (DPS) output abnormality 3.

While in the drum potential correction, a patch for control is not output with the V1 getting to more than 350V. When this condition is detected 5 times in succession, the error code is displayed.

 

C-2811

Drum potential sensor (DPS) data abnormality. While in the drum potential correction, no convergence is obtained even after correction is made more than 10 times. When this condition is detected 5 times in succession, the error code is displayed.

 

C-2812

Transfer current auto adjustment abnormality. The auto adjustment of the transfer current has not completed.

 

C-2815

Developing bias auto adjustment abnormality. The auto adjustment of the developing bias has not completed.

 

C-2816

Drum charger capacity deterioration.

When the charger grid/ developing bias is in excess of the limit of correction, lower the developing potential/ fogging margin potential in steps of 50V. As a result, less than 50V of the difference with the target charger potential is detected 10 times in succession.

 

C-2821

The toner supply prohibition status is not released 1.

Even though the TCR sensor (TCRS) output increases, the number of the toner supply prohibition status continuity is detected 30 times, and more than 2.5V of the TCRS output value is detected.

 

C-2822

The toner supply prohibition status is not released 2.

The number of the toner supply prohibition status continuity becomes 100 times.

Main body: Motor

abnormality

C-3102

Fusing pressure release motor (M33) operation time abnormality 1.

When M33 moves from the release position to the pressure position, the fusing pressure home sensor (PS58) does not turn ON within a specified period of time.(PRO 951 is unimplemented)

The same abnormality occurs when the fusing unit exclusively for PRO 951 is set to PRESS 1250/1250P/1052.

 

C-3103

Fusing pressure release motor (M33) operation time abnormality 2.

The fusing pressure home sensor (PS58) ON is not detected within a specified period of time after the main power turns ON. When M33 moves from the pressure position to the release position, PS58 does not turn ON within a specified period of time. (PRO 951 is unimplemented)

The same abnormality occurs when the fusing unit exclusively for PRO 951 is set to PRESS 1250/1250P/1052.

Main body: Fusing set abnormality

C-3104

Abnormality when the fusing unit used exclusively for PRESS1250/1250P/1052 or EF-120 is set to PRO 951.

An error is detected in the following conditions with the fusing unit used exclusively for PRESS1250/1250P/1052 or EF-102 is set to PRO 951.

In case that either of the fusing pressure home sensor (PS58), fusing pressure position sensor /1 (PS59), fusing pressure position sensor /2 (PS60) and fusing pressure position sensor /3 (PS61) turns ON when both the ADU knob set and the fusing unit set are detected.

Main body: Motor

abnormality

C-3201

Drum motor (M24) power abnormality + 24V power abnormality.

When M24 turns ON, error detection signals (blowout of ICP and the 24V cut off) are detected.

 

C-3202

Web motor (M24) power abnormality.

An error detection signal (blowout of ICP) is detected when M24 turns ON. At this time, an error detection signal (24V cut off) is not detected.

Main body: Fusing high temperature abnormality

C-3501

Thermistor /1 (TH1) high temperature abnormality (software).

TH1 detects a temperature of 244°C or above 10 times in a period of 0.5second.

 

C-3502

Thermistor /3 (TH3) high temperature abnormality (software).

TH3 detects a temperature of 230°C or above 5 times in a period of 1second.

 

C-3503

Thermistor /1 (TH1) high temperature abnormality (hardware).

TH1 detects the fusing abnormality detection 1.

 

C-3504

Thermistor /3 (TH3) high temperature abnormality (hardware).

TH3 detects the fusing abnormality detection 4.

Main body: Fusing low temperature abnormality

C-3801

Thermistor /1 (TH1) high temperature abnormality (software).

TH1 does not get to 50°C when a specified period of time has elapsed after the main power switch (SW1) turns ON for the fusing ON control.

 

C-3802

Thermistor /3 (TH3) high temperature abnormality (software).

TH3 does not get to 50°C when a specified period of time has elapsed after the main power switch (SW1) turns ON for the fusing ON control.

Main body: Fusing sensor abnormality

C-3901

Thermistor /1 (TH1) high temperature abnormality (long time/software).

TH1 detects a temperature of 240°C or above 60 times in a period of 0.5second.

 

C-3902

Thermistor /3 (TH3) high temperature abnormality (long time/software).

TH3 detects a temperature of 220°C or above 30 times in a period of 1second.

 

C-3903

Thermistor /1 (TH1) high temperature abnormality 1 (hardware).

TH1 detects the fusing abnormality detection signal 2.

 

C-3904

Thermistor /3 (TH3) high temperature abnormality (hardware).

TH3 detects the fusing abnormality detection 5.

 

C-3905

Thermistor /1 (TH1) high temperature abnormality 1 (hardware).

TH1 detects the fusing abnormality detection signal 3.

 

C-3906

Thermistor /3 (TH3) high temperature abnormality (hardware).

TH3 detects the fusing abnormality detection 6.

Main body: Fan abnormality

C-4301

Image processing cooling fan (FM12) rotation abnormality + 24V power abnormality.

The abnormal status is detected twice in succession after FM12 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

С-4З0З

Image processing cooling fan (FM12) rotation abnormality 1.

The FM12 EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, error detection signal (24V cut off) is not detected.

 

C-4304

Image processing cooling fan (FM12) rotation abnormality 2.

When the print is started, the EM signal of FM12 turns ON.

 

C-4305

Charger suction fan (FM3) rotation abnormality + 24V power abnormality.

The abnormal status is detected twice in succession after FM3 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-4307

Charger suction fan (FM3) rotation abnormality 1.

The FM3 EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, error detection signal (24V cut off) is not detected.

 

C-4314

Front cooling fan (FM18) rotation abnormality + 24V power abnormality.

The abnormal status is detected twice in succession after FM18 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-4316

Front cooling fan (FM18) rotation abnormality.

The FM26 EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, error detection signal (24V cut off) is not detected.

Main body: Image processing abnormality

C-4701

FIFO address abnormality for the printer.

While in the image write, the expansion processing of image data that is read in is not correctly terminated.

 

C-4702

Compression input FIFO abnormality.

An error interrupt occurs with the compression/ expansion chip FIFO.

 

C-4703

Elongation abnormality. Due to the elongation of data the compression of which is not completed, the destruction of the compressed data and the abnormal length of data, an elongation abnormality is detected.

 

C-4705

Printer time out.

 

C-4706

Expansion device access abnormality.

While in the image write, despite of no resource provided, an inappropriate processing such as accessing to the elongation device is made.

 

C-4708

Expansion device access abnormality.

When accessing to the memory device, a defective software is detected.

 

C-4709

Memory time out.

 

C-4720

Shift amount abnormality while in the repeat.

When the shift amount (used for cutting margin, etc.) while in the repeat is negative (-).

 

C-4721

The Centering Adjustment is too late.

The print operation starts before the paper centering adjustment is terminated. (The Centering Adjustment is too late)

 

C-4722

The creation of the PWM gamma curve failed.

A PWM gamma curve is not created properly.

 

C-4725

LPH board (LPHB) connection abnormality. Due to the disconnection of the LPHB connector, no connection is available with the overall control board.

 

C-4850

Segmentation abnormality. The overall control software accesses an illegal address.

 

C-5010

Communication error between the overall control board (OACB) and the printer control board (PRCB).

Any of the following error is detected during data reception between OACB and PRCB.

Main

body:Power

abnormality

C-5101

Fusing motor (M1) speed abnormality.

An error detection signal is detected twice in succession within a specified period of time after M1 was turned ON.

Main body: Main relay operation malfanction

C-5102

Monitor the detection signal of RL1 turning ON and 24 VICP blowout since the main tray (RL1) firstly turns ON after the power source turns ON, and detect the abonormality 5 times in a row during a specified period of time.

Main body: Fan abnormality

C-5311

Suction cooling fan /1 (FM6) rotation abnormality + 24V power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-5313

Suction cooling fan /1 (FM6) rotation abnormality 1.

The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (24V cut off) is not detected.

 

C-5317

Cooling fan /1 (FM1) rotation abnormality + 24V power abnormality.

The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-5319

Cooling fan /1 (FM1) rotation abnormality 1. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, an error detection signal (24V cut off) is not detected.

 

C-5320

Cooling fan /2 (FM2) rotation abnormality + 24V power abnormality.

The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-5322

Cooling fan /1 (FM1) rotation abnormality 1. The FM2EM error detection signal is detected twice in succession within a specified period of time after FM2 was turned ON. At this time, an error detection signal (24V cut off) is not detected.

 

C-5326

Cooling fan /1 (FM1) rotation abnormality 2. When the print is started, the EM signal of FM1 turns ON.

 

C-5327

Cooling fan /1 (FM1) rotation abnormality 2. When the print is started, the EM signal of FM2 turns ON.

 

C-5328

Suction cooling fan /1 (FM6) rotation abnormality 2.

When the print is started, the EM signal of FM6 turns ON.

 

C-5329

Abnormality of the fan connected to ADU drive board.

The EM error detection signal is detected twice in succession within a specified period of time after ADU cooling fan /1 (FM14), /3 (FM13), sensor cooling fan /1 (FM16) and registration cooling fan (FM17) connected to ADU drive board were turned ON. At this time, the door close detection of the door open/close sensor /1 (PS1), /2 (PS2) and PF door open/close sensor (PS70) is detected 10 times in succession.

 

C-5330

Suction cooling fan /2 (FM7) rotation abnormality + 24V power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-5332

Suction cooling fan /2 (FM6) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (24V cut off) is not detected.

 

C-5337

De-curler fan /1 (FM29) rotation abnormality.

The FM29EM error detection signal is detected twice in succession within a specified period of time after FM29 was turned ON. At this time, the door close is detected.

 

C-5338

De-curler fan /2 (FM30) rotation abnormality.

The FM30EM error detection signal is detected twice in succession within a specified period of time after FM30 was turned ON. At this time, the door close is detected.

 

C-5339

Transfer belt cleaning fan (FM27) rotation abnormality.

When the print is started, the EM signal of FM27 turns ON.

 

C-5340

Rotation abnormality of fans equipped in ADU.

The EM error signal is detected twice in succession within a specified period of time after ADU cooling fan /2 (FM15), belt cooling fan (FM37) and reverse cooling fan (FM38) was turned ON. At this time, the door close is detected.

 

С-5З41

Collection pipe cooling fan (FM34) rotation abnormality + 24V power abnormality.

The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

С-5З4З

Collection pipe cooling fan (FM34) rotation abnormality 1.

The FM34EM error detection signal is detected twice in succession within a specified period of time after FM34 was turned ON. At this time, an error detection signal (24V cut off) is not detected.

 

C-5344

Collection pipe cooling fan (FM34) rotation abnormality 2.

When the print is started, the EM signal of FM34 turns ON.

 

C-5345

Toner bottle cooling fan (FM35) rotation abnormality + 24V power abnormality.

The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-5347

Toner bottle cooling fan (FM35) rotation abnormality 1.

The FM35EM error detection signal is detected twice in succession within a specified period of time after FM35 was turned ON. At this time, an error detection signal (24V cut off) is not detected.

 

C-5348

Toner bottle cooling fan (FM35) rotation abnormality 2.

When the print is started, the EM signal of FM35 turns ON.

Main body:

Scanner

abnormality

C-6101

Scanner motor (M27) movement time abnormality + 24V power abnormality.

The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is

 

 

started. At this time, an error detection signal (24V cut off) of M27 is detected.

 

C-6102

Scanner motor (M27) power abnormality.

The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected.

 

C-6103

Scanner motor (M27) movement time abnormality.

The scanner home sensor (PS51) or the APS sensor /1 (PS52) does not turn ON within a specified period of time after the home position search is started. At this time, an error detection signal (blowout of a fuse/24V cut off) of M27 is not detected.

Main body: Fan abnormality

C-6301

Scanner cooling fan (FM19) rotation abnormality + 24V power abnormality.

The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (24V cut off) is detected.

 

C-6302

Scanner cooling fan (FM19) power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected.

 

C-6303

Scanner cooling fan (FM19) rotation abnormality.

The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected.

Main body: Image processing abnormality

C-6701

Filter coefficient abnormality.

When processing images, a filter coefficient cannot be created normally.

 

C-6702

Scanner FIFO abnormality. FIFO address abnormality for compression is indicated.

 

C-6703

SVV length abnormality. After negation of SVV, the compression of images that are read in and their development into the page memory are not terminated within a specified period of time.

 

C-6704

Scanner time out.

 

C-6705

Compression device access abnormality.

When writing images, in spite of no resource provided, an inappropriate processing such as an access to the compression device is made.

 

C-6706

SVV OFF abnormality. While in the image read, SVV does not turn OFF within a specified period of time and the preparation for scanning the next page cannot be started.

 

C-6707

Shading correction abnormality (GA abnormality)

 

C-6708

AOC/AGC adjustment level abnormality. AOC/AGC adjustment error occurs due to the abnormality related to the exposure lamp or the trouble of the read section.

 

C-6709

Abnormality of the adjustment data by resolutions.

The adjustment data evacuated by resolutions is not available.

 

C-6710

Density conversion gamma curve creation abnormality.

A density conversion gamma curve cannot be created normally.

 

C-6717

N-in-1 page area abnormality.

Due to an image area abnormality of the memory, images cannot be developed on the memory.

 

C-6719

The original skew adjustment is too late.

The scan operation starts before the original skew adjustment is terminated.

 

C-6721

AGC retry.

The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs.

 

C-6801

Initial communication error between the image processing board (OACB) and the operation board /1 (OB1).

An initial communication from the main body to the operation panel is not sent within 30 seconds after the power is turned ON.

DF: DF abnormality

C-8001

Sending error between the main body and DF. Although the main body sent out data according to the data transmission request by the DF, the same request is received again.

 

C-8002

Reception error between the main body and DF. Checksum error or SRGA reception error is detected twice in succession while in the reception in serial communication.

 

C-8003

Initial communication error between the main body and DF.

When the main power switch (SW1) is ON, there is no response to the initial communication request from the main body to the DF even after a specified period of time elapses.

 

C-8201

Tray up-down motor (M305) abnormality.

 

C-8301

Cooling fan /Lt (FM301) and /Rt (FM302) abnormality

 

C-8401

Original registration sensor /Lt (PS306) abnormality.

 

C-8402

Original conveyance sensor (PS308) abnormality.

 

C-8403

Original reverse sensor (PS309) abnormality

 

C-8404

Non-volatile memory error

 

C-8405

Reverse jam sensor (PS304) abnormality.

 

C-8406

Original reverse-exit sensor (PS313) abnormality.

 

C-8407

Original skew sensor /Fr (PS312) abnormality.

 

C-8408

Original skew sensor /Rr (PS311) abnormality.

 

C-8409

Original registration sensor /Rt (PS318) abnormality.(DF-615 only)

 

C-8410

Centering sensor /Fr (PS320) abnormality. (DF-615 only)

 

C-8411

Centering sensor /Rr (PS321) abnormality. (DF-615 only)

 

C-8412

Multi feed detection boards /S (MFDBS) and /R (MFDBR)

abnormality(DF-615 only)

Main Body: IC

Controller

abnormality

C-A001

Transfer error to the main body image memory

 

C-A002

Hard disk /2 (HDD2) abnormality.

 

C-A003

IC cooling fan (FM39) lock abnormality.

 

C-A004

Unregulations IC error occurs.

 

C-A005

Version abnormality between SSD (SSD) and hard disk /2 (HDD2).

The SSD version is different from the version information in HDD2.

 

C-A006

Hard disc /2 (HDD2) abnormality 1 while in the security ON.

While in the security ON, the unlocking of the HDD results in a failure due to the mismatched password of the hard disk /2 (HDD2).

 

C-A007

Hard disc /2 (HDD2) abnormality 2 while in the security ON.

Unlocked HDD2 is detected while in the security ON.

 

C-A008

Hard disk /2 (HDD2) is unformatted.

An unformatted HDD2 is detected.

 

C-A009

Controller memory abnormality.

 

C-A101

Controller initial communication abnormality.

Main body:

Communication

error

C-C101

Initial communication error between the overall control board (OACB) and the printer control board (PRCB).

No response is returned from PRCB even after a specified period of time after the main power switch (SW1) and the sub power switch (SW2) turn ON. Or ISW information is not written on PRCB.

 

C-C102

Initial communication error between the overall control board (OACB) and the printer control board (PRCB).

Communication error from PRCB is detected. Or transmission is not completed.

 

C-C103

Communication error between the overall control board (OACB) and the operation board /1 (OB1). Communication error from OB1 is detected. Or transmission is not completed.

 

C-C104*

ISW write abnormality 1 of the printer control board.

 

C-C105

ISW write abnormality 2 of the printer control board.

 

C-C106

ISW time out error.

No normal header is transmitted within a specified period of time after ISW is started.

 

C-C107

ISW download abnormality.

An error is detected while downloading ISW.

 

C-C108

ISW write abnormality on the overall control board. An error is detected because ISW data cannot be written on the overall control board (OACB).

FS: FS-532 ISW unwritten

C-C109

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the FS firmware.

LS: LS ISW unwritten

C-C111

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (1st tandem).

 

C-C112

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (2nd tandem).

FD: FD ISW unwritten

C-C113

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the FD firmware.

SD: SD-506 ISW unwritten

C-C114

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the SD firmware.

PB: PB ISW unwritten

C-C116

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the PB firmware.

GP: GP-501 ISW unwritten

C-C117

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the GP firmware.

RU: RU-510 ISW unwritten

C-C118

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU firmware.

RU: RU-509 ISW unwritten

C-C119

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the RU program.

DF:

Communication

error

C-C120

ISW write abnormality on DF.

When the main power switch (SW1) is ON, unwritten area by the ISW is detected in the DF control program.

LS: LS ISW unwritten

C-C121

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the LS firmware (3rd tandem).

FS: SD-510 ISW unwritten

C-C124

When the sub power switch (SW2) turns ON, ISW unwritten area is detected in the SD firmware.

IC:

Communication

error

C-C125

ISW write abnormality of controller.

The firmware is not written on ICB or an error is detected during the ROM check.

 

C-C130

Wrong serial number. The serial number for the different machine is specified.

DF wrong installation

C-C131

DF-615 is installed to PRO 951. Or, DF-615 is installed to PRESS1250/1052.

Wrong

installation of image processing board

C-C132

The image processing board (IPB) used exclusively for PRESS1250/1250P/1052 is installed to PRO951. Or, IPB used exclusively for PRO951 is installed to PRESS1250/1250P/1052.

Common API

unmatched

version

C-C136

When the version differs between Common API for the overall control and IC controller.

HDD:

Communication

error

C-D001

Hard disk /1 (HDD1) initialization abnormality. HDD1 is defective, or the connector is poorly connected.

 

C-D002

JOB_RAM storage abnormality.

The JOB information cannot be stored on the hard disk /1 (HDD1).

 

C-D003

Hard disk /1 (HDD1) periodic cleaning abnormality.

While in a periodical cleaning, opening the rote to hard disk is not succeeded.

 

C-D004

Hard disk /1 (HDD1) access defective.

HDD1 is defective, or the connector is poorly connected.

 

C-D010

Hard disk /1 (HDD1) overwrite erase execution. HDD1 overwrite erase is executed.

Common API related HDD file crushed

C-D080

The common API related HDD file on the hard disk / 1 (HDD1) is crushed

HDD:

Communication

error

C-E001

Message queue error. The message queue is insufficient or destroyed.

 

C-E002

Message parameter value error.

The parameter value is in excess of the permissible limits.

 

C-E003

Source task error.

The ID of the task that sends the message queue is undefined.

 

C-E004

Receiving event error.

The receiving event of the message is undefined.

 

C-E005

Memory access abnormality.

 

C-E006

Header readout address abnormality.

 

C-E007

DRAM memory abnormality.

An error is detected in the DRAM memory check at the start.

Корзина
 Корзина
В корзине нет товаров

Уважаемый(-ая), Гость!
Вы не зарегистрированы.
Ваша скидка: 0%
Новости
Новости
13.12.21Сервисный центр раскатных цилиндров (печатных барабанов) Riso, Ricoh, Duplo!
30.11.20Доступны к заказу узлы и запасные части Riso EZ300
24.11.20Доступны к заказу узлы и запасные части Riso EZ230
31.08.20Доступны к заказу узлы и запасные части Riso EZ200
18.08.20Условия отгрузки запасных частей
Статьи
Статьи
Konica Minolta bizhub PRO 1050 - модель, которую отличают низкие эксплуатационные расходы
bizhub PRO 1050 – это надёжная система, выполненная в стальном корпусе и созданная для удовлетворения потребностей высокопроизводительных сегментов
Коника Минолта запускает новую высокопроизводительную систему: bizhub PRO 920
bizhub PRO 920 является новейшим дополнением в линейке производственных печатных устройств Коника Минолта. Он соединяет в себе качество копирования, печати и точность сканирования. Это устройство идеально для офисов с большим объемом печати, в отделе подготовки печатной продукции и цифровой печати.
Серия Konica Minolta bizhub PRO удостоена награды BERTL
Серия черно-белых производительных систем от Konica Minolta, представленная машинами bizhub PRO 920 и bizhub PRO 1050e, высоко оценена лабораторией BERTL за удобство использования и качество печати.
Обзор Aficio SP 3400SF
В уникальном МФУ Aficio SP 3400SF специалисты компании Ricoh сумели соединить весь необходимый набор для качественной и бесперебойной офисной работы.
Что нового в Ricoh MP 4002 и MP 5002
Продолжаем обзор Ricoh Aficio MP 4002 и MP 5002
Акции
Акции
Акция: тефлоновый вал, верхний вал печки к печатной технике по специальной акционной цене
Акция: OPC Drum, фотобарабан, фотовал к печатной технике по специальной акционной цене
Акция: прижимной, резиновый и нижний вал печки к печатной технике по специальной акционной цене
Акция: сепараторы бумаги
Акция: ролики подачи бумаги
Акция: разделительные пластины